background image

INFORMATION

Warnings

About this manual

GARO LS4 MINI is an EVSE station for Mode-3 AC charging up 
to 43kW.

Below are some example of standard features:

•  Fixed cable for Mode-3 EV charging.
•  Suitable for installation on wall or ground stand.
•  LED status indication.
•  Upgradeable firmware*
•  Visible energymeter
•  OCPP via 4G or LAN*
•  RFID reader for secure authorization (not activated as default)*

LS4 MINI supports following features:

•  External DLM energy meter*
•  Cluster installation of multiple LS4 MINI via Ethernet*
•  Cluster installation of multiple LS4 MINI, LS4 and GLB+ via 

Ethernet*

* Require certified technician

Dielectric Voltage Withstand Test is not allowed on 
LS4 MINI

This equipment should not be used by anyone (including 
children) with reduced physical, sensory or mental 
capacity, or anyone lacking in experience or knowledge, 
unless they are provided with supervision or prior 
instruction in how to use the equipment by the person 
responsible for their safety.

LS4 MINI is designed exclusively for charging electric 
vehicles.

LS4 MINI must be grounded according to local country 
installation requirements.

Do not install or use the LS4 MINI near flammable, 
explosive, harsh, or combustible materials, chemicals, or 
vapors.

Turn off the electrical power at the circuit breaker before 
installing, configuring, cleaning or maintenance.

Use LS4 MINI only within the specified parameters.

Never spray water or any other liquid directly at LS4 
MINI. Never spray any liquid onto the charge handle or 
submerge the charge handle in liquid. Store the charge 
handle in the dock to prevent unnecessary exposure to 
contamination or moisture.

Do not use this equipment if it appears to be damaged or 
if the charging cable appears to be damaged.

Do not modify the equipment installation or any part of the 
product.

Do not touch the terminals with fingers or any other 
objects.

Do not insert foreign objects into any part of LS4 MINI

INFORMATION

This document contains general descriptions which are verified to 
be accurate at the time of printing. However, because continuous 
improvement is a goal at GARO, we reserve the right to make 
product and software modifications at any time. This range is 
subject to continual product development. Errors, typos and 
omissions excepted. Latest manuals can always be found at 
https://www.garo.se

3

EN

Содержание LS4 MINI 43kW

Страница 1: ...LS4 MINI 43kW Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380312 1 0 Assembly instructions End User Instructions EN GARO AB EN...

Страница 2: ...arnings 3 Cautions 4 Notes 4 Content 4 INSTALLATION 5 USER MANUAL 7 Normal use 7 LED indications 7 Dimensional sketch 11 Electrical diagram 12 Technical specifications 15 Service Maintenance 16 Servic...

Страница 3: ...ing to local country installation requirements Do not install or use the LS4 MINI near flammable explosive harsh or combustible materials chemicals or vapors Turn off the electrical power at the circu...

Страница 4: ...g hit by vehicles is minimized Ensure that the charging cable is positioned so it will not be stepped on driven over tripped on or subjected to damage or stress Unroll the charging cable to prevent it...

Страница 5: ...the fuse and cable information in the Installation form located in the installation manual that is included in the box 3 Mount the LS4 MINI on a wall or on a pedestal figure 1 6 Note Wall installatio...

Страница 6: ...L3 N 6Nm PE 2 5 10mm 5Nm 16 50mm 10Nm AL L1 L2 L3 N 2 5 16mm 5Nm 25 50mm 10Nm PE 2 5 10mm 5Nm 16 50mm 10Nm Pedestal Accessory Article number 354386 0 8Nm 0 05 figure 4 figure 5 figure 3 4x ALU CU ada...

Страница 7: ...g station detects that the cable is connected but is yet to detect the EV Blinking green 30 second blink Whenever during operation Charging station have received command from backend to start charging...

Страница 8: ...ent charging cable if available Blinking green 30 second blink Connect the charging cable or verify that cable is connected correctly Check the intake on the EV for obstructions dirt Firm blue No erro...

Страница 9: ...current in backend charger configuration OperatorCurrentLimit Check motor locking wiring and connection for damages Verify that locking mechanism rod and arm are not stuck Verify that the connector is...

Страница 10: ...2DC on the output terminals when red black cables were disconnected then it has detected an earth fault in one of the DC powered components controllers upper PCB router switch etc inside the charging...

Страница 11: ...AUTHORIZED available A Vehicle not connected Firm blue CHARGING occupied C Vehicle connected ready CHARGING suspendedEV B Vehicle connected not ready Blinking blue Reserved Firm red RCD triggered grou...

Страница 12: ...minal Block 1 XD1 Type2 Charging Cable FB1 RCCB 200 201 External Meter Terminal Block 200 201 FC3 Fuse Charge Controller and Powersupply Q1 Main Breaker XPE2 Protection Earth Terminal Block 2 SP Surge...

Страница 13: ...L2 i L3 i N L1 o L2 o L3 o SC 1 2 3 4 5 6 9 8 N N L1 L2 L3 L1 L2 L3 CC1 B Modbus CC1 A Modbus CC1 B Modbus CC1 A Modbus CC1 B Modbus CC1 A Modbus L1 N 12V DC 230 V T1 CC1 Relais 23 12V 0V 0 75 BLACK R...

Страница 14: ...A2 Modbus WA Relais 23 WA Relais 24 Eth 1 10 100 RJ45 HEAT CC1 4G Down side Type 2 Charge cable RED Up Side Antenna AC Terminal QA1 A1 CP 0V 12V P E PE 1A 1B C P PP P1 B 1B 0V DC Terminal P1 A 1A 12V...

Страница 15: ...g type Mode 3 Charging method AC Charging Protection class IP54 Mechanical impact resistance IK10 Temperature range 25C 40C Weight 25kg Standard cable length 7 5m Rated current impuls withstand 10kA R...

Страница 16: ...ntenance form Check point for annual maintenence Status Value Comment remark Visual check outside cabinet LED indication lit Check cables connectors connector pins Check color foil and instructions Ch...

Страница 17: ...UAL Installation Form LS4 MINI Model M nr ELECTRICAL INSTALLATION DATA Group fuse A Supply cable dimension FUNCTION TEST Testbox Date Sign Installer Company Name Owner Customer Name Installation addre...

Страница 18: ...18 EN...

Страница 19: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...

Отзывы: