ABOUT THIS MANUAL

INFORMATION

This document contains general descriptions which are verified to 
be accurate at the time of printing. However, because continuous 
improvement is a goal at GARO, we reserve the right to make 
product and software modifications at any time. This range is 
subject to continual product development. Errors, typos and 
omissions excepted. Latest manuals can always be found at 
https://www.garo.se

GARO LS4 is an EVSE station for Mode-3 AC charging up to 
43kW.

Below are some example of standard features:

•  Fixed cable for Mode-3 EV charging.
•  Suitable for installation on ground.
•  LED status indication.
•  Upgradeable firmware*
•  Visible energymeter
•  OCPP via 4G or LAN*
•  RFID reader for secure authorization (not activated as default)*

LS4 supports following features:

•  External DLM energy meter*
•  Cluster installation of multiple LS4 via Ethernet*
•  Cluster installation of multiple LS4 MINI, LS4 and GLB+ via 

Ethernet*

* Require certified technician

SAFETY INFORMATION

The LS4 stations are designed exclusively for charging 
electric vehicles.

All installation must be carried out by an authorized 
installer and comply with local country installation 
regulations.  If any questions, please contact your local 
electrical authority.

Refer to local standards and regulations not to exceed 
charging current limitations.

To even out the load, it is important to rotate the phases 
when connecting several of LS4 stations to the same 
system. Note that 1-phase charging is common in electric 
vehicles and L1 (left side) and L2 (right side) in the LS4 is 
used for this purpose.

Ventilation signal from EV is not supported. This means that 
test of “State D” is not possible.

Adapters for charging connectors are not allowed to be 
used.

Cord extension sets for charging cable is not allowed to 
be used.

Do not use private power generators as a power source 
for charging.

Incorrect installation and testing of the LS4 stations could 
potentially damage either the vehicles battery and/or the 
LS4 itself.

Do not operate the LS4 stations in temperatures outside its 
operating range – see technical specifications.

INFORMATION

3

EN

Содержание LS4 43kW

Страница 1: ...GARO LS4 43kW Installation Manual EN GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se Manual 380316 1 0 EN...

Страница 2: ...utions 4 General Information 4 Content 4 INSTALLATION 5 NORMAL USE 9 Electrical diagram 14 Technical specifications 17 Service information 17 Form for annual service and maintenance 18 Warranty Condit...

Страница 3: ...FETY INFORMATION The LS4 stations are designed exclusively for charging electric vehicles All installation must be carried out by an authorized installer and comply with local country installation reg...

Страница 4: ...er behind the front door When contacting GARO support please have the M number available LS4 stations that are pre configurated for backend solution have the ChargeBoxID CBID labeled under the M numbe...

Страница 5: ...the provided ethernet router switch located ie in the LS4 master Se example of ethernet wiring diagram picture 6 7 In cases with LS4 stations connected in a grid installation of the LS4 stations need...

Страница 6: ...picture 1 picture 2 Cu 2 5Nm Al 4Nm OPTION INSTALLATION CU AL 6 EN...

Страница 7: ...0 8Nm 0 05 picture 3 picture 4 picture 5 INSTALLATION 7 EN...

Страница 8: ...P CAT6 cable to router switch 5pcs LS4 connected with TP CAT6 cable to router switch picture 6 picture 7 Example of DLM meter installation Modbus address 2 9600 8 1 no parity Terminals 200 A 201 B DLM...

Страница 9: ...ing station have received command from backend to start charging and is waiting for car to connect Firm Car connected Charging is ongoing state C Car connected Charging is paused state B Blinking When...

Страница 10: ...g without success Contact installer or GARO Support please have M number available Check car settings that can influence charging i e gear in parking mode doors closed car locked etc Present a valid R...

Страница 11: ...kend charger configuration OperatorCurrentLimit Check motor locking wiring and connection for damages Verify that locking mechanism rod and arm are not stuck Verify that the connector is properly inse...

Страница 12: ...black cables were disconnected then it has deteced an earth fault in one of the DC powered components controllers upper PCB router switch etc inside the charging station If LED light DC OK remains tu...

Страница 13: ...Vehicle not connected Firm CHARGING occupied C Vehicle connected ready CHARGING suspendedEV B Vehicle connected not ready Blinking Reserved Firm RCD triggered groundFailure Residual current detected...

Страница 14: ...XN1 Neutral Terminal Block QA1 Contactor XPE1 Protection Earth Terminal Block 1 XPE2 Protection Earth Terminal Block 2 CT1 Current transformer 100A CT2 Current transformer 100A CT3 Current transforme...

Страница 15: ...CT3 XPE2 XPE1 P1 CC1 A MOD CC1 B MOD AC Terminal 35 Feritte 525 Ohm DOUBLE INSULATED CABLE 16 1 5 XN1 L N EB1 Heater Cold Option 10A FC3 I 2 1 P1 11 P1 11 XD1 CP 201 200 External Energy Meter A1 A2 Q...

Страница 16: ...o t o M Motor HS1 Relais 13 Motor HS2 Relais 14 GND2 Modbus B2 Modbus A2 Modbus WA Relais 23 WA Relais 24 RJ45 CC1 Down Side 0V 12V DC Terminal A1 A2 K3 OUT IN OUT IN CC RFID 12V GND HEAT Top Card KF1...

Страница 17: ...ID output power 250mW SERVICE INFORMATION Care and maintenance GARO charging station LS4 The warranty will only remain valid if service is performed Service is performed once a year and must be docume...

Страница 18: ...cation by 2 or 3 flashes from LED s Turn off the electrical power Check gaskets Check torque for mains terminals Check torque for LS4 fixing screws towards ground wall Check torque on standard compone...

Страница 19: ...l number 7 Warranty does not cover damage occurred by incorrect use of equipment use of any non original spare parts lack of maintenance or faults caused by disassembly of the product or unauthorized...

Страница 20: ...ANTIFORMUL R LS4 Model M no Electrical installation data Group fuse A Supply cable dimension Function Test Testbox EV model Date Sign Installer Company Name Owner Customer Name Installation adress WAR...

Страница 21: ...DECLARATION OF CONFORMITY 21 EN...

Страница 22: ...GARO AB Box 203 SE 335 25 Gnosj Phone 46 0 370 33 28 00 info garo se garo se EN...

Отзывы: