7094LP Manual
To program the number of senders for each tank:
1. The fresh and black tanks can have one or two senders, so
this information must be programmed into the display. The
grey and galley tanks can only have one sender each, so no
programming is possible for the number of senders.
2. To program the number of senders for each tank, the display
needs to enter the sender programming mode. This should
only be done at the time of installation, there is no reason
to change the number of senders afterward. Make sure that
the number of senders programmed into the display matches
with the number of senders connected, otherwise the display
will show an error.
3. To enter the sender programming mode, press and hold down
the button for the tank to be programmed, the display may
show a level or an error message for that tank.
4. While continuing to hold down the button for the tank, press
and hold down the LPG button. The display will immediately
show ”dIA” (diagnostics), continue to hold down both buttons
until the display enters the programming mode, this should
take about 5 more seconds.
5. When the programming mode is entered, the display will
show “FrS” if doing the number of senders for the fresh tank
or “bLS” if doing the black tank. When this occurs release
both buttons.
6. The display will now show “1SE” (one sender) or “2SE” (two
senders), based on what is currently programmed into the
display. These are the only two options, the display will not
work with more than two senders per tank.
7. To change the number of senders, press the tank button, each
time the button is pressed the display will switch to the other
number.
8. When the display shows the correct number of senders, press
the LPG button to exit the programming mode. All of the tanks
will need to be calibrated individually using this procedure.
The battery voltage is calibrated at the factory, this should never
need to be changed.