Page 13
7094LP Manual
1. The installation consists of mounting the display inside the RV,
cutting and fastening the senders to the sides of the holding
tanks, connecting wiring, and programming the display.
2. Mount the display by cutting a hole in the wall 3” wide by 1
7/8” high and bringing the wiring out through the hole to
connect to the display panel connector.
3. Connect the wiring according to the following table. It is easier
to connect the wiring to the display connector first, and then
plug the connector into the display panel. The sender needs
to be grounded to a single ground wire from the display.
4. Determine where to mount the senders on the tanks. They
will need to have a flat area on the side of the tank large
enough so the whole width of the sender is in contact with
the side of the tank, all the way from the top to the bottom
of the tank. Make sure that any metal is at least an inch away
from the sender. Clean the area well so that there is no dust,
grease, oil, water, etc., that would prevent the adhesive on the
sender from sticking.
5. Measure the height of the tank to determine how long the
senders should be. For tanks less than 13” tall, follow step 6.
For tanks greater than 13” tall, follow step 7.
6. For tanks less than 13” tall, a single sender is used. The
sender ends should be 1/4” to 3/4” away from the top and
bottom of the tank, to allow for the thickness of the tank top
and bottom and any bows in them (see the diagrams). The
senders are calibrated to account for this distance from the
bottom of the tank. The sender is cut to the nearest even 1.5
inch in length, for example, a system with a tank height of
11.75 inches, cut the sender to be 10.5 inches long, this allows
5/8” at each end when the sender is centered vertically on the
tank. IMPORTANT: Do not cut the sender shorter than
4-1/2 inches! The sender will not work if it is cut less than
4-1/2 inches.
CHAPTER 6 - INSTALLATION GUIDE
(NEW OEM INSTALLATIONS ONLY)
Wire Color
Function
Red 18 gauge
+12V power input to monitor
Black 18 gauge
Ground
Blue 18 gauge
Tank senders
Green 18 gauge
LPG sender