CHAPTER 4 - DISPLAY CALIBRATION
To calibrate the LPG sender:
1. The LPG tank must be full when the sender is calibrated,
otherwise the calibration will be invalid. Fill the LPG tank by
using an alternate measurement method, such as weight, a
spit valve, or a mechanical gauge on the tank.
2. To calibrate, press and hold down the LPG button, the display
will show some LPG level.
3. While continuing to hold down the LPG button, press and
hold down the BLACK button. Continue to hold down both
buttons for about 5 seconds until the display shows “LPG”.
4. When this occurs release both buttons, the display will
show “CAL” for a second and then shut off, completing the
calibration procedure.
5. The LPG can be recalibrated as many times as desired,
although recalibration should not be needed unless the LPG
tank sender or the display has been replaced.
To program the LED brightness:
1. If the display is to be used inside the coach, the LED brightness
should be low. If it is to be used in the service bay area where
sunlight can reach it, the LED brightness should be high.
2. To program the LED brightness, the display needs to enter the
brightness programming mode. To do this, press and hold
down the LPG button, the display will show the LPG level.
3. While continuing to hold down the LPG button, press and hold
down the GREY button. Continue to hold down both buttons
for about 5 seconds until the display shows “bri” to indicate
the brightness programming mode. When this occurs release
both buttons.
4. The display will now indicate the brightness that is currently
programmed by showing “b-1”, “b-2”, “b-3”, or “b-4”, where
“b-1” is the minimum brightness and “b-4” is the maximum
brightness.
5. Press the GREY tank button to increase brightness, or the
FRESH tank button to decrease brightness.
6. When the display shows the correct brightness, press the LPG
button to exit the programming mode.