HD-2 Operation and Installation Manual
Page 7
Power Plug
Plug the EIA connector attached to the power cord supplied into the receptacle on the
back of the HD-2.
Fuse Block
Located behind the removable panel on the front side of the HD-2, there are six
separate fuses, one each for 100, 110, 120, 220, 230 & 240 VAC power. Only one fuse
is used at a time. Therefore, for any voltage range, the two unused fuses of the same
value can be used as spares.
Location
The degausser must be placed on a flat, hard surface. Keep at least a 6 inch (15cm)
distance from any object that may interfere with the cooling fan exhaust located on the
backside of the degausser. As a general rule, media not intending to be erased should
be kept about 60cm (2 feet) away.
Cooling
Forced air-cooling is used to maintain safe operating temperatures within the
degausser. The air intake is located on the back panel and the exhaust is through the
holes in the top panel. To ensure proper cooling, do not block the air-intake or exhaust
and maintain at least a 15cm (6 inches) distance from the back of the degausser to any
obstacle.