GTX 33X and GTX 3X5 ADS-B Maintenance Manual
Rev. 6
Page 6-3
6.2 GTX 33/33D
WARNING
Ensure that the aircraft power is off before removal or reinstallation of the GTX 33/33D.
Unplug any auxiliary power supply.
This section contains procedures and requirements for removal and installation of equipment installed
under STC SA01714WI. After removal and reinstallation, the GTX 33/33D return to service procedures
must be performed in accordance with section 9.
Removal
1. Gain access to the transponder.
2. Unlock the GTX 33/33D handle by loosening the Phillips screw on the handle.
3. Pull the handle upward to unlock the GTX 33/33D. Gently remove the unit from the rack.
Reinstallation
1. Visually inspect the connectors to verify there are not bent or damaged pins. Repair any damage.
2. Gently insert the GTX 33/33D into its rack. The handle should engage the locking mechanism
used to secure the unit in place.
3. Press down on the GTX 33/33D handle to lock the unit into the rack.
4. Lock the handle to the GTX 33/33D body by tightening the Phillips head screw.
Figure 6-2 GTX 33 Mounting Rack/Connector Assembly
115-00629-00
125-00002-00
011-00950-03
211-63234-11
(2 PLACES)
211-60234-08
(2 PLACES)
330-00053-01 (BNC)
OR
330-00053-02 (TNC)
(1 OR 2 PLACES)
212-00022-00
(1 OR 2 PLACES)
NUT SUPPLIED
WITH 330-00053-XX
330-00185-62
011-01169-01
Содержание GTX GTX 330D
Страница 33: ...190 00734 11 GTX 33X and GTX 3X5 ADS B Maintenance Manual Rev 6 Page 3 10 Figure 3 6 G1000 Transponder Control ...
Страница 34: ...190 00734 11 GTX 33X and GTX 3X5 ADS B Maintenance Manual Rev 6 Page 3 11 Figure 3 7 G1000 Transponder Control ...
Страница 42: ......
Страница 100: ...190 00734 11 GTX 33X and GTX 3X5 ADS B Maintenance Manual Rev 6 Page 8 7 ...
Страница 101: ...190 00734 11 GTX 33X and GTX 3X5 ADS B Maintenance Manual Rev 6 Page 8 8 ...
Страница 133: ......