GMA 245/245R Installation Manual
Rev. 6
Page 3-6
3.3.2 Shield Termination Technique – Method A.1 (Standard)
NOTE
For the following steps please refer to
(as appropriate), and
1. The appropriate number of Backshells will be included in the particular LRU connector kit.
Figure 3-3 Method A.1 for Shield Termination
2. At one end of a shielded cable (item 2,
) measure a distance between
“Window Min” to “Window Max” (Table 3-6) and cut a window (max size 0.35”) in the jacket to
expose the shield (item 4, Figure 3-3). Use caution when cutting the jacket to avoid damaging the
individual braids of the shield. When dealing with a densely populated connector with many
cables, it may prove beneficial to stagger the windows throughout the “Window Min” to “Window
Max” range. If staggering is not needed the “Ideal Window” length is recommended.
Suggested tools to accomplish the window cut:
•
Coaxial Cable Stripper
•
Thermal Stripper
•
Sharp Razor Blade
Table 3-6 Shielded Cable Preparations for Garmin Connectors
Backshell-
Size
Number
of Pins
Std/HD
Float Min
(inches)
Float Max
(inches)
Ideal Float
(inches)
Window
Min
(inches)
Window
Max
(inches)
Ideal
Window
(inches)
44 Pin
44
1.5
2.5
2.0
3.0
5.5
4.5