Appendix C – Construction and Validation of Structures
Page C-2
GDL 69/69A Installation Manual
Revision E
190-00355-02
5.
Fasten a 36 inch loop of suitable material such as fishing line, braided wire, or other similar
material having a breaking strength of at least 150 lbs, diagonally between two of the screws.
Then fasten another loop diagonally between the other two screws, adjusting the length of the
loop so it exactly matches the first.
6.
Hook a calibrated force gauge through both loops and apply a sustained pull for at least 3 seconds
in each of the other three directions (upward, sideward and forward) at the above calculated
forces shown for your particular unit and rack. The values are found in Tables C-1 and C-2.
7.
Examine the support structure carefully. If there has been damage or permanent deformation, the
structure is not suitable and must be replaced with one which is strong enough to withstand the
test loads. Examine all aircraft stringers, bulkheads and skin surfaces, which may have direct or
indirect contact with the fabricated shelf. If it is determined that no damage or permanent
deformation has occurred, the structure is of sufficient strength and the GDL 69/69A equipment
rack may be permanently mounted on it.
Figure C-1. Upward Static Load Test
Figure C-2. Forward Static Load Test
Содержание GDL 69/69A
Страница 1: ...190 00355 02 June 2006 Revision E GDL 69 69A Installation Manual...
Страница 2: ...This Page Intentionally Left Blank...
Страница 52: ...Limitations Page 6 2 GDL 69 69A Installation Manual Revision E 190 00355 02 This Page Intentionally Left Blank...
Страница 56: ...STC Data Page A 2 GDL 69 69A Installation Manual Revision E 190 00355 02 This Page Intentionally Left Blank...
Страница 69: ......
Страница 70: ......