Installation Procedure
GDL 69/69A Installation Manual
Page 2-3
190-00355-02
Revision E
2.4.2 Remote
Mount
Rack
The remote mount rack can be installed in a variety of locations, such as the electronics bay, behind the
instrument panel, under the seat or behind the rear baggage area. Leave sufficient clearance between the
GDL 69/69A and any obstruction. Install the rack in accordance with AC43.13-2A Chapter 2 Radio
Installations. The remote mount rack should be mounted to a surface known to have sufficient structural
integrity to withstand additional inertial forces imposed by a 1.86 pound unit (1.72 lbs. for GDL 69). If it
is necessary to build a shelf or bracket to mount the GDL 69/69A rack or if is not certain that the chosen
location is of sufficient structural integrity, refer to Appendix C. Refer to Figure 1-2 for the GDL 69/69A
remote mount rack dimensions. The rack can be mounted vertically using four 8-32 pan head screws
(MS35206, AN526 or equivalent.) It can also be mounted horizontally using four 6-32 100° counter-sunk
flathead screws (MS24693, AN507R or equivalent.) Ensure that the rack has a ground path to the
airframe by having at least one mounting screw in contact with the airframe to minimize radiated
electromagnetic interference (EMI).
GDL 69
P/N: 011-00986-00
P/N: 001-00987-00
GDL 69A
BACK PLATE ASSEMBLY
P/N: 011-00796-35
CONNECTOR KIT ASSEMBLY
P/N: 011-00997-00
GDL 69 REMOTE MOUNT RACK
P/N: 115-00658-00
Figure 2-2. GDL 69/69A Remote Mount Rack
2.4.3 G1000
Modular
Rack
The G1000 modular rack is used to install the GDL 69/69A in the standard G1000 integrated avionics
system rack. This modular rack may be mounted behind the instrument panel or in the avionics bay. Refer
to Figure 1-3 for the GDL 69/69A G1000 modular rack dimensions. This STC covers the installation of
the GDL 69/69A modular rack into the installed G1000 integrated avionics system rack, but does not
cover the installation of the G1000 integrated avionics system rack.
2.4.4 Remote
Switches
Installation of rocker switches should be made on a flat surface and located at a convenient location
within the cabin. Each rocker switch installed must be properly marked of its function. Use of rocker
switches vs. toggle switches will prevent the possibility of raising and lowering the volume at the same
time or raising and lowering the channels at the same time. Wire used for discrete switches should be 24
AWG (MIL Spec M22759) and should be routed as appropriate, avoiding kinking or sharp bends. Figure
2-3 shows typical rocker switches.
Содержание GDL 69/69A
Страница 1: ...190 00355 02 June 2006 Revision E GDL 69 69A Installation Manual...
Страница 2: ...This Page Intentionally Left Blank...
Страница 52: ...Limitations Page 6 2 GDL 69 69A Installation Manual Revision E 190 00355 02 This Page Intentionally Left Blank...
Страница 56: ...STC Data Page A 2 GDL 69 69A Installation Manual Revision E 190 00355 02 This Page Intentionally Left Blank...
Страница 69: ......
Страница 70: ......