Installation Procedure
GDL 69/69A Installation Manual
Page 2-19
190-00355-02
Revision E
NOTE
When inserting the GDL 69/69A into the Remote Mount Rack, it may be possible for the Pivot
Pin (2) to fit between the unit and the mount rack without going into the slot of the Locking Plate
(3). If the Cam Head (2) does not seat in the slot of the Locking Plate (3), the unit will not firmly
engage with the mount rack and the unit could come loose from the rack.
4.
With the unit firmly engaged with the mount rack, lower the Locking Lever Handle (1). Then,
insert and tighten the Locking Lever Handle Securing Screw (4) to mechanically secure the unit
to the Mount Rack.
GDL 69/69A
011-00986-00/011-00987-00
Locking Lever Handle (1)
Locking Lever Handle
Cam Head (2)
Locking Plate (3)
Locking Lever Handle
Securing Screw (4)
GDL 69/69A Remote Mount Rack
115-00658-00
Figure 2-11. GDL 69/69A Installation
CAUTION
Do not use excessive force when inserting the GDL 69/69A into the rack. This may
cause damage to occur to the connectors, unit, and/or unit rack. If heavy resistance is felt
during installation,
STOP
! Remove the GDL 69/69A and identify the source of
resistance. The unit is designed with a key and the back plate is designed to float in the
unit rack. Check to ensure the rear plate is not bound by the connector harness.
Содержание GDL 69/69A
Страница 1: ...190 00355 02 June 2006 Revision E GDL 69 69A Installation Manual...
Страница 2: ...This Page Intentionally Left Blank...
Страница 52: ...Limitations Page 6 2 GDL 69 69A Installation Manual Revision E 190 00355 02 This Page Intentionally Left Blank...
Страница 56: ...STC Data Page A 2 GDL 69 69A Installation Manual Revision E 190 00355 02 This Page Intentionally Left Blank...
Страница 69: ......
Страница 70: ......