G300 Installation Manual – Post Installation Checkout and Calibration Procedures
Page 9-1
190-00921-01
Revision A
9.
Post-Installation Checkout and Calibration Procedures
The checkout procedures in this section are recommended to be performed after installing the G300, the
calibration procedures are required to be performed after installing the G300. It is assumed that the
person performing these checks is familiar with the aircraft, has a working knowledge of typical avionics
systems, and has experience using the test equipment defined in this section.
The calibration procedures in this section are performed in the configuration mode. To enter
configuration mode, hold down the left-hand softkey while powering on the GDU 37X. In a two-display
system hold down the left-hand softkey on the PFD while powering on the unit.
All three status boxes on the GSU Page (config mode) must indicate a positive state (green check marks)
before performing any calibration procedures. The GMU 44 and GSU 73 units must be communicating
with the GDU 37X, and the GPS antenna must have clear view of the sky or a GPS repeater to produce
positive status indications.
The CONFIG GSU Page must be “unlocked” by pressing the softkeys 2, 3, 4 in order (Figure 9-1) to
select a calibration procedure.
Softkey #1
Softkey #2
Softkey #3
Softkey #5
Softkey #4
Figure 9-1 – Softkey Positions
NOTE
All procedures in this section require that the GPS receiver is receiving sufficient satellite
signal to compute a present position. This requires outdoor line-of-site to GPS satellite
signals or a GPS indoor repeater
NOTE
As these procedures involve engine runup and moving the aircraft, it is recommended
that the installer read this entire section before beginning the checkout procedure.
NOTE
Unless otherwise noted, all procedures apply to both one-display and two-display
systems.
CAUTION
Be sure to check all aircraft control movements before flight is attempted to ensure that
the wiring harness does not touch any moving part.
Содержание G300 for Cessna SkyCatcher
Страница 1: ...190 00921 01 March 2009 Revision A G300 Installation Manual...
Страница 36: ...Page 4 8 G300 Installation Manual GSU 73 Revision A 190 00921 01 This page intentionally left blank...
Страница 44: ...Page 6 4 G300 Installation Manual Antennas Revision A 190 00921 01 This page intentionally left blank...
Страница 94: ...Page 10 12 G300 Installation Manual Troubleshooting Revision A 190 00921 01 This page intentionally left blank...