190-00820-08 Rev. A
Cirrus Perspective
™
by Garmin – Pilot’s Guide for the SR20/SR22/SR22T
SY
STEM
O
VER
VIEW
FLIGHT
INSTRUMENTS
EIS
AUDIO P
ANEL
& CNS
FLIGHT
MANA
GEMENT
HAZARD
AV
OID
ANCE
AFCS
ADDITIONAL
FEA
TURES
APPENDICES
INDEX
593
APPENDIX A
SYSTEM MESSAGE ADVISORIES
NOTE
:
This section provides information regarding Perspective
™
message advisories that may be displayed
by the system. Knowledge of the aircraft, systems, flight conditions, and other existing operational priorities
must be considered when responding to a message.
This section describes various Perspective
™
System message advisories. Certain messages are issued due
to an LRU or LRU function failure. Such messages are normally accompanied by a corresponding red ‘X’
annunciation as shown previously in the Perspective
™
System Annunciations section.
PRIMARY FLIGHT DISPLAY & MULTI FUNCTION DISPLAY
Message Advisory
Comments
DATA LOST
– Pilot stored data was
lost. Recheck settings.
The pilot profile data was lost. System reverts to default pilot profile and settings. The
pilot may reconfigure the MFD & PFD with preferred settings, if desired.
XTALK ERROR
– A flight display
crosstalk error has occurred.
The MFD and PFD are not communicating with each other. The Perspective
™
system
should be serviced.
PFD1 SERVICE
– PFD1 needs service.
Return unit for repair.
The PFD and/or MFD self-test has detected a problem. The Perspective
™
system
should be serviced.
MFD1 SERVICE
– MFD1 needs
service. Return unit for repair.
MANIFEST
– PFD1 software
mismatch, communication halted.
The PFD and/or MFD has incorrect software installed. The Perspective
™
system should
be serviced.
MANIFEST
– MFD1 software
mismatch, communication halted.
PFD1 CONFIG
– PFD1 config error.
Config service req’d.
The PFD configuration settings do not match backup configuration memory. The
Perspective
™
system should be serviced.
MFD1 CONFIG
– MFD1 config error.
Config service req’d.
The MFD configuration settings do not match backup configuration memory. The
Perspective
™
system should be serviced.
SW MISMATCH
– GDU software
version mismatch. Xtalk is off.
The MFD and PFD have different software versions installed. The Perspective
™
system
should be serviced.
PFD1 COOLING
– PFD1 has poor
cooling. Reducing power usage.
The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the Perspective
™
system should be serviced.
MFD1 COOLING
– MFD1 has poor
cooling. Reducing power usage.
PFD1 KEYSTK
– PFD1 [key name] is
stuck.
A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by pressing
it several times. The Perspective
™
system should be serviced if the problem persists.
MFD1 KEYSTK
– MFD1 [key name]
is stuck.
CNFG MODULE
– PFD1 configuration
module is inoperative.
The PFD1 configuration module backup memory has failed. The Perspective
™
system
should be serviced.
PFD1 VOLTAGE
– PFD1 has low
voltage. Reducing power usage
The PFD1 voltage is low. The Perspective
™
system should be serviced.
MFD1 VOLTAGE
– MFD1 has low
voltage. Reducing power usage
The MFD voltage is low. The Perspective
™
system should be serviced.
Содержание Cirrus Perspective SR20
Страница 1: ... Cirrus SR20 SR22 SR22T Integrated Avionics System Pilot s Guide ...
Страница 2: ......
Страница 655: ......