Page 6-8
G1000/GFC 700 Post Installation Checkout Procedure - Hawker / Beechcraft King Air C90
Revision 5
190-00682-00
10. On PFD1, go to the GIA Page Group. Go to the RS-232 / ARINC 429 CONFIG page.
11. Verify that GIA1 is selected in the SELECT UNIT field.
12. Observe the data indicators for all configured RS-232 and ARINC 429 channels (except
GIA DEBUG), including the GRS 77 and GDC 74 ARINC 429 channels.
13. Verify all DATA indicators are GREEN, indicating the channels are receiving data as
shown below:
14. Activate the cursor and select GIA2 in the SELECT UNIT field, then press the ENT key.
15. Repeat Steps 12 and 13.
16. On PFD1, go to the CAN / RS-485 CONFIGURATION page in the GIA Page Group.
17. Verify that GIA1 is selected in the SELECT UNIT field.
18. Observe the data indicators for all configured RS-485 channels.
19. Verify all DATA indicators are GREEN, indicating the channels are receiving data as
shown: