Part Number 4532879 1/15
13
Section 2
Installation
Critical Requirements
SUMMARY OF OPERATIG CODITIOS
Max. Tolerance of Nominal
Supply Voltage
+6 /-10 %
Supply frequency
50/60 Hz
Ingress Protection class
IP X0 (Protection by customer is
required.)
Minimal Diameter of
Induction Pan
5” (12cm)
Maximum Ambient
Temperature
In Storage > -4°F to +158°F
(-20°C to +70°C)
In Operation >+ 41°F to +104°F
(+5°C to +40°C)
Maximum Relative Air
Humidity
In Storage > 10% to 90%
In Operation > 30% to 90%
Clearance from Materials
Min. 1.18” / 30mm
Maximum Air Flow
70.63cfm/120m
3
per hour
Minimum opening: total sum of
10.075in
2
/6500mm
2
is required.
ELECTRICAL COMPARTMET
To protect the induction unit and wiring, we recommend
isolating the generator, the coil carrier sheets, and the wires
in separate electrical compartments inside the cabinet
(Figure B, below).
The illustration below shows a simplified representation of
an installation.
otice
To ensure reliability of the induction unit, the custom
built counter / island suite / compartments must have
sufficient ventilation for the exhaust.
The in-take air and exhaust air must not mix. Depending
on the air path and the amount of natural air movement,
it is highly recommended to install a fan or fans on the
cabinet to pull hot exhaust air away from the electronic
equipment, or to provide a separate exhaust air plenum.
Failure to provide adequate ventilation will cause
the induction unit to overheat, to reduce power, or to
shutdown.
Figure
B
Figure
A
FRONT
C
E
D
G
H
F
D
E
FRONT
C
E
D
G
H
F
D
E
I
I
A. (Figure A)
All components are installed inside one single
compartment and the wires are exposed.
B. (Figure B)
The interior space of the cabinet is divided. The
unit and wiring are protected inside the upper
compartment. Extra storage space can also be
created.
C. Fresh air intake (Air intake kit provided).
D. Hot air exhaust openings.
E. Air exhaust vents/fans installed on the cabinet.
NOTE: Additional fans and cooling controls are the
responsibility of the customer and installer.
F. Clearance. See section
“Installation Clearance” on
page 14
G. Built-In Compact Line induction generator.
H. Power switch cable (x2), length= 1m / 39.4inch, to
connect the operation unit (power switch) to the
induction generator.
I. Main power cable (not provided).