11
6. Mounting Instructions
CAUTION!
THE BATTERY TAMPER BUTTON MUST BE HELD
DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY,
TO ENSURE THE BATTERY DOOR WILL CLOSE, THE AC QUICK
CONNECTOR WILL ATTACH TO THE ALARM, AND THE ALARM
WILL ATTACH TO THE TRIM RING.
NOTE: PLEASE ENSURE THAT BATTERY IS INSTALLED PRIOR
TO MOUNTING OF SMOKE ALARM.
A trim ring is provided on the back of the smoke alarm. This trim ring
is removed by holding the trim ring and twisting the smoke alarm in
the direction indicated by the turn to remove arrow. The trim ring is
secured to the smoke alarm by a trim lever.
Caution! The cover is a sealed unit and has no removable
serviceable parts! Do not tamper.
1. Secure a suitable junction box near
the position of the smoke alarm,
ensure the quick connect cable
length is long enough to reach the
junction box for termination to be
made.
2. Connect active, neutral and switch
line to the smoke alarm cable
using the terminal connection
block provided. Secure these
terminals inside the junction box.
3. Punch out the suitable fixing holes
on the trim ring and then pull the
AC connector through the centre
of the trim ring.
4. Secure the trim ring to the ceiling
using the fixing holes provided.
Connect the 9V battery (back up)
into the battery compartment.
Ensure the locks on the AC
connector snap firmly into place.
If the back up 9V battery is already
loaded in the Battery compartment,
pull out the battery pull tab.
SQUEEZE
CONNECTOR
LOCKING
ARMS AND PULL
INSTALL
MARKS
REMOVE
FIGURE 4A
FIGURE 4B