This unit is equipped with a 2-speed fan interface (Grills
manufactured post grill serial number 0010CL0036).
McDonalds stores built post May 2000 are equipped with
the capability of a 2-speed interface. In the event that a store
is a capable 2-speed fan store, and the grill is not a 2-speed
fan unit, a separate 2-speed installation kit is available upon
request at a set billable price to the store.
Units equipped with a 2-speed fan interface still require
the 5-wire interlock cord, in addition to a separate 3-wire
extension cord supplied from the hood exhaust system.
2-speed installation instructions are available upon request.
2-speed activation will occur at the following times:
LOW SPEED (all active AFTER (1) ONE MINUTE)
1. All platens (equipped and are active 2-speed fan grills)
go into the standby mode. (For standby mode see page
23).
2. All platens (equipped and are active 2-speed fan grills)
are in the OFF mode.
3. All platens (equipped and are active 2-speed fan grills)
are idle (in the up position).
4. When grill is initially turned on for initial heat up in the
morning.
HIGH SPEED (Active immediately)
1. A cook cycle on at least 1 platen (equipped and are active
2-speed fan grills) is initiated.
2. When grill is initialized using the main ON/OFF Master
Power switch for 1 minute.
3. CLEAN MODE.
16
UNIT INSTALLATION
2-SPEED FAN INTERFACE INFORMATION (STANDARD AND WESTERN CANADA)
IMPORTANT
: RATING PLATE FOR THIS EQUIPMENT
IS LOCATED IN TWO PLACES. ONE IS LOCATED
INSIDE BACK PANEL ON LEFT SIDE, SECOND
RATING PLATE LOCATED UNDER FRONT CONTROL
PANEL ON CENTER.
A competent person must install this appliance
This appliance should be connected to a potential equalization
system. To facilitate this, a labeled equipment potential
bonding point is fitted to the rear of the grill.
It is recommended that this grill is connected to a residual
current (earth leakage) devise with a tripping current not
exceeding 30mA. The leakage current of this grill will not
exceed 5mA.
This grill may be supplied with a seven-pin socket, as
specified by McDonald’s Corporation, for installation in
new grill stations. This socket is supplied loose with the
grill, complete with its wiring harness. This socket MUST
be located on the underside of the grill, using the mounting
holes provided and wired to the internal terminal block
according to the wiring diagram provided on the rear of
the appliance and in this manual. This socket allows for
disconnection from the supply with all pole separation of at
least 3mm.
For connection to existing older grill stations, please refer
to your Kitchen Equipment Supplier for a conversion kit
that allows connection to two power supply cords and one
interlock cord. This kit must be connected according to the
instructions and wiring diagram supplied with it and the
warning labels supplied with the kit must be applied to the
grill.
CAUTION
: Prior to installation, check the electrical supply
to ensure input voltage and phase match the equipment
voltage rating and phase. See data plate located rear left side
of grill. Back panel removal is required.
Grill is to be located directly under ventilation system and fit
securely with grill locks attached.
Grill must be level front to back, side to side and
diagonally.
WARNING
: Electrical appliances must be electrically
grounded in accordance with local codes or in the absence
of local codes, with national electric code ANSUI/NFPA
- latest version.
WARNING
: Installer Note - This grill is designed for
connection to a special interlock system. Check receptacle-
wiring diagram before connecting.
Configuration may vary by area or country. Verify with the
local regional operations department.