Gas Input ratings shown here are for installations up to 2,000-ft. (610m) above sea level. Specify altitudes over 2,000 ft.
Commercial cooking equipment requires an adequate ventilation system. For additional information, refer to the National Fire Protection
Association’s standard NFPA96, “Vapor Removal from Cooking Equipment.” (NOTE: For North America only)
Please specify gas type when ordering.
7-3/4"
[197mm]
38-1/4"
[972mm]
3/4"
[19mm]
17-3/4"
[451mm]
TOP VIEW
2"
[51mm]
FLUE: 2-3/8" x 5"
[60mm x 127mm]
3/4" N.PT.
GAS INLET
11-1/2"
[292mm]
38"
[965mm]
32-1/8"
[816mm]
25-3/8"
[645mm]
SINGLE DECK
FR ONT VIEW
1-1/4"
[32mm]
34"
[864mm]
54-9/16"
[1386mm]
3/4" REAR
GAS INLET
32-1/8"
[816mm]
32-1/8"
[816mm]
6-1/4"
[159mm]
14-3/4"
[375mm]
32-1/8"
[816mm]
35-7/16”
[900mm]
32-1/8"
[816mm]
1-1/4"
[32mm]
DOUBLE DECK
FR ONT VIEW
D
H
H
1" REAR
GAS INLET
Single-Deck
Models
Int. Dimensions :In (mm)
Ext. Dimensions: In (mm)
Ship Wt
Ship Dim.
W
H
D
W
H *
D
Lbs/kg
Cubic Ft.
Standard Depth
29 (736)
24 (610)
24 (610)
38 (965)
57-1/2 (1461)
41-1/4(1048)
515/230
64
Deep Depth
29 (736)
24 (610)
28 (711)
38 (965)
57-1/2 (1461)
44-1/2(1130)
545/245
64
Double-Deck
Models
Int. Dimensions: In (mm)
Ext. Dimensions: In (mm)
Ship Wt.
Ship Dim.
W
H
D
W
H *
D
2@Lbs/kg
Cubic Ft.
Standard Depth
29 (736)
24 (610)
24 (610)
38 (965)
70-1/2 (1791)
41-1/4(1048)
1030/465
128
Deep Depth
29 (736)
24 (610)
28 (711)
38 (965)
70-1/2 (1791)
44-1/2(1130)
1090/490
128
* Height with legs or with standard casters. Height with low profile casters (double deck) is 68-1/2” (1740mm).
Models
Input Ratings, Nat & Pro
Electrical Specifications
BTU/hr
kW Equiv.
Gas Inlet
120V/1Ph.
240V/1Ph.
Single Deck
60,000 /80,000*
17. 6 /23.4*
(1 )@ 3/4" NPT
(1)@9.8A
(1)@ 5.2A
Double Deck
120,000 /160,000*
35.2/46.9*
(1 )@1" NPT
(2)@9.8A
(2)@ 5.2A
Operating Pressure:
Natural: 4" WC (10 mbar)
Propane: 10" WC (25 mbar)
Max 13.8" WC @ 70°F (21°C)
NOTE: Data applies only to
North America
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V 0.6 HP, 2-speed motor; 1430 and 1670 rpm 60Hz
3. (240V units) 200-240V, 0.6 HP, 2-speed motor; 1430 and 1670 rpm, 60Hz
4. A 6 ft. line cord is provided for each 120V deck with a (NEMA #5-15P) plug.
5. Garland recommends a separate 15 AMP circuit for each 120V unit.
(includes
fan motor)
DIMENSIONS & SPECIFICATIONS
*Optional burner imput rating for natural gas only.
Document # G_GO_OM_CONVENTION_4607458 – 06/21
6
Содержание MCO-GS-10S
Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...