Appendix A Specifications
M100G1AC 1U host system specifications
Dockings
Front holders
Voltage input
AC: 90-240 VAC Auto-Select
-48 (-75 - -36) VDC
Size
438mm x 586 mm x 44 mm ( 17.24” x 23.07” x
1.73”)
Width x Depth x Height
Operating humidity
0%–90%, non-condensing
Operating temperature
0°C – 40°C (32°F - 104F)
Storage temperature
-20C–65C (-4F–149F)
Fans
4 hot-swappable fans
4 wire connections on each fan (12V,GND,TACH and
PWM)
Specifications of one fan (in maximum operation
condition):
SPL: 61dB(A)
Current: 0.92A
Air flow: 28.6 CFM
EMC certifications
Class B FCC, CE, VCCI
MTBF*
> 150,000 hours
M1001Gxx (50um)
M1001Gxx: Fiber 40Gigabit Ethernet specifications - (100GBase-SR4) Adapters
IEEE standard / Network topology
Fiber Gigabit Ethernet, 100GBase-SR4 (850nM)
Data transfer rate
100G per port
Cables and operating distance
Multimode fiber:50um
*50m maximum on OM3 MMF
*75m maximum on OM4 MMF
Theoretical distance – Defined as half a distance
Size
102.2mm x161.9 mm x 40.5 mm (4.02” x 6.37” x 2”)