Packet Broker
EdgeLens Inline Security Packet Broker | INT40G2XR44 | 1.19.5
6. Reverse Bypass
If enabled and the primary inline appliance and the secondary inline appliance
port(s) fail, loss of link or heartbeats. The TX will be disabled on both of the
network ports. The RX for both network ports remain on.
Figure 7 Primary-Secondary Tap (Reverse Bypass)
7. Revertive
If enabled and the primary inline appliance port(s) fail, loss of link or
heartbeats, the system will switch to the secondary inline appliance.
When the issue with the primary inline appliance is resolved, has link and
heartbeats. The traffic will automatically revert back to the primary inline
appliance. This option also affects the switching from bypass to inline. If
disabled, the system is designed to switch from bypass to the secondary inline
appliance. If the primary inline appliance restores first, has link and heartbeats, a
manual switch to the primary inline appliance is required. If enabled and the
primary inline appliance restores first, the system will switch from bypass to the
primary inline appliance.
8. Taps Coupled
If enabled all switching functionality supported by Tap 1 and Tap 2 are coupled
together. Taps coupled will couple the revertive option for both Taps. If taps
coupled is enabled or disabled the other tap options can not be selected until the
accept and save are selected. Then the other tap options will become active.
9. Select Accept to save updates. Save must additionally be selected on the Tap panel.
10. Select Cancel to return the Tap panel.
11. Select Back to Primary to manually switch the traffic from the secondary inline appliance to the
primary inline appliance. This function is independent for each tap unless they are coupled. Then
selecting Back to Primary on either tap, will cause both taps to switch.
12. Select Save to save updates.
13. Select Cancel to return the Bypass Taps panel.