6) Pin Code Set(for emergency Engine start / default is 1111)
- Vehicle Status & Start Button : KEY OFF, Press Start Button for 10seconds without foot braking
- Set mode engage : Start Button LED blinking 2 times with 2 times of Buzzer
- Set Pin Code (Start Button press time is Pin Number)
① Input 1
st
pin number then wait – Start Button LED blinking 2 times with 2 times of Buzzer
② Do the same as ① until 4
th
pin code
after finished, please try to do emergency engine start without remote FOB key
7) How to change Pin Code
- Vehicle Status & Start Button: KEY-ON, Press Start Button for 10 seconds without foot braking
- Set mode engage : It will turn to OFF from ON then LED blinking 2 times with 2 times of Buzzer
- Set Pin code (Start Button press time is Pin Number)
① Input 1
st
pin number then wait – Start Button LED blinking 2 times with 2 times of Buzzer
② Do the same as ① until 4
th
pin code
after finished, please try to do emergency engine start without remote FOB key
5) Low Battery Voltage detect & Auto start(Default – Off)
- Vehicle Status : Door open, KEY-OFF (ACC OFF)
- Sequence & Vehicle response : Press
+
for 2 seconds then check 2 times of Buzzer
-
Set Mode engage: Press
1 time then wait 5 seconds, check 2 times of buzzer
(after buzzer if no press button, set mode will be OFF)
- Turbo Timer Set: Press 1 second interval then wait for 5seconds
4) Starter Motor Setting (Default – 1 second)
- Vehicle Status : Door open, KEY-OFF (ACC OFF)
- Sequence & Vehicle response : Press
+
for 2 seconds then check 2 times of Buzzer
-
Set Mode engage: Press
4 times then wait 5 seconds, check 2 times of buzzer
(after buzzer if no press button, set mode will be OFF)
- Turbo Timer Set: Press
1 second interval then wait for 5seconds
GARIN System
8
Press
1
st
2
nd
3
rd
Time
1 sec
2 secs
3 secs
Press
1
st
2
nd
3
rd
4
th
5
th
6
th
Voltage
11.6V
11.8V
12.0V
12.1V
12.2V
12.3V
MYKEY Classic Timer & Auto Start Setting
※ Every pressing button, there will be buzzer
sound for confirmation of press.