background image

                                                                                                                                                            

28

3. Operation 

3.1. Entering User Menu 

When the system is in Disarmed mode (Alarm 
off), entering a valid user code can access the 
user menu, the system can then be Away 
armed or Bypass armed via this menu. 

When the first numberic key is pressed, the 
display will show: 

 

  E n t  e r    C o d e        
             

¿

. . .        

 

when the complete PIN code is keyed in 
followed by

 OK

 key, within 10 sec., the first two 

li

nes of the user menu is shown: 

 

    A w a  y    A r  m            
    H o  m e    A r  m            

 

A flashing dot will appear next to 

Away Arm

the complete menu list consists of: 

 

    A w a  y    A r  m            
    H o  m e    A r  m            
  B 

y p 

a s s         

    L  o  g                       
    C o n t  r  o l    P S S      

 

These items can be scrolled through by using 
the 

T

&

S

 keys. 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

)

 

If there is any fault event occurred, no 
matter if the fault condition has been 
rectified or not, when you enter the 
PIN Code followed by 

OK

, the 

following screen will be displayed. 

 

  F 

a u 

l t  D 

s p 

     

    A w a  y    A r  m            
    H o  m e    A r  m            
  B 

y p 

a s s         

    L  o  g                       
    C o n t  r  o l    P S S      

 

And the cursor stays at

 Fault Dsp

 

position.  To arm the system, please 
see the section 

Forced Arming 

below.    

)

 

If there is any SMS message saved, 
the screen will display SMS for SMS 
message reading. 

 

 

 

)

 

If you press    key while the 

Alarm 

off

 is displayed, a 

Enter Code 

promp 

screen will be displayed.  After you 
enter your pin Code, the above screen 
will also be displayed. 

)

 

After 30 seconds of key-inactivity, the 
system will automatically exit User 
Menu and return to

 Alarm off

 mode. 

 

 

3.2. Away (Alarm ON) Mode  

3.2.1. Arming the system 

If the system is in Disarmed mode (Alarm off), 
to arm the system.   

Step 1. 

Enter your PIN code and press

 OK

 key.  

The display will show

    A w a y   A r  m            
    H o m e   A r  m            
    B y p a s  s                 
    L o g                      

and the cursor stays at 

Away Arm 

 

Step 2. 

Press

 OK

 key and the screen will 

display. 

 

  T i m e  T 

 E 

x i t   

      3 0  s e c     

 
The defined EXIT Delay is displayed on the 
second line, and is counting down.  During the 
EXIT Delay period, the exit sound plays, unless 
it has been chosen to switch off. 

Step 3.

 When the Exit Delay time is up, or the 

Entry

 Door Contact (Final Door Set 

Function programmed to be 

On

) is 

closed, the Control Panel will sound a 
long beep.  The 

Alarm On

 will display 

on the screen and the system is in 
Arm mode. 

    A l a r m   O N            
    0 7 : 2 5    1  6    D  e c    

<

<

N

N

O

O

T

T

E

E

>

>

 

 

)

 

When 

Final Door Set Option

 is set to 

Off

, the Control Panel enters 

Alarm 

On

 mode only when the Exit Delay 

time is up. 

Содержание CTC-1132

Страница 1: ...Installation Programming Operating D D 29 APR 2009...

Страница 2: ......

Страница 3: ...Home Entry Time ____________________________________________________ 12 2 3 8 H Exit Time Home Exit Time _______________________________________________________ 13 2 3 9 Door Chime __________________...

Страница 4: ...______ 27 2 11 Reset GSM ___________________________________________________________________ 27 3 Operation _________________________________________________________________ 28 3 1 Entering User Menu...

Страница 5: ...s this key to move the cursor and scroll the display upwards T Key Programming mode press this key to move the cursor and scroll the display downwards Key Programming mode use this key to delete a dig...

Страница 6: ...ion the AC power adapter is used to supply power to the Control Panel and at the same time recharge the battery z When the battery is fully charged it can provide back up power for a period of at leas...

Страница 7: ...location for the Control Panel to be installed Step 2 Apply the AC Power You will hear a long beep Alarm On will be displayed on the first line and 00 01 01 Jan displayed on the second line of the scr...

Страница 8: ...the cursor downward or upward The screen is also scrolled down or up respectively The following items can be selected Wa l k T e s t T e l S e t t i n g G e n S e t t i n g s S p c S e t t i n g s D...

Страница 9: ...ne set phone number must be entered or the Panel will not dial out at the Alarm situation Step 3 Key in your phone number Step 4 Press OK key The screen will then prompt you to choose V o i c e R e p...

Страница 10: ...er will be deleted 2 2 2 Record Message z This menu is for you to record your voice messages P l a y M e s s a g e R e c o r d M s g S t o p z With a total capacity of 20 sec you are allowed to record...

Страница 11: ...nt to change any part of the recorded message just follow the same procedure to record a new message for that part The new message will overwrite the previous one 2 2 3 Test Report Control unit allows...

Страница 12: ...r 85 sec before returning to selection menu Pressing will return to the menu with the list of numbers 2 3 General Settings In General Settings menu the following parameters can be programmed at your d...

Страница 13: ...structed from Steps 2 7 When done press key and the screen returns to General settings menu setting the PIN code is completed N NO OT TE E In Step 5 if the code is not correct a Code is not correct pr...

Страница 14: ...C o d e O k Step 3 Press key the next screen will ask you to enter your new PIN code and repeat it for double confirmation Step 4 Follow the same steps as described in Set your own pin code to edit 2...

Страница 15: ...ay Emergency alarm voice message for Voice Reporting refer 2 2 1 Telephone Numbers z The Duress Code consists of 4 digits and is not activated as default by the factory To Set Duress Code Step 1 Use t...

Страница 16: ...Control Panel raises an alarm and sends an alarm report z Options available are Disable alarm immediately 10 sec 20 sec up to 70 sec in 10 sec increments z Press OK on A Entry Timer and the following...

Страница 17: ...e no door chime when Entry or Away Entry point DC or PIR is triggered at Disarmed mode When Door Chime is enabled the system will make a Ding Dong sound to inform user that a DC or PIR at Entry Point...

Страница 18: ...Min in 1 Min increments A l a r m L e n g t h 3 mi n V O K z 3 minutes is set as factory default z If Disable is selected when the Control Panel receives an alarm signal the panel siren and internal...

Страница 19: ...cted 9 Fire alarm 9 Water alarm 9 Personal panic alarm 9 Medical emergency 9 Tamper alarm 9 GSM failure The alarm reporting will be sent immediately even if the audible alarm is delayed 2 4 7 Verifica...

Страница 20: ...Mobility Timer with selected countdown period Options available are Disable 4 hours 8 hours and 12 hours If the Mobility Timer is enabled it will count down the pre programmed time length When the tim...

Страница 21: ...chosen ON CTC 1132 will be able to receive the check in signals from its system devices to indicate their proper functioning D i s a b l e o 8 H o u r s 1 2 H o u r s 2 4 H o u r s z 8 Hours is set as...

Страница 22: ...r device Pressing key will abort the procedure and will not learn in the device Depending the type of the device different screens will then be displayed accordingly for further configuration purpose...

Страница 23: ...y Door Contact is triggered the Control Panel will start an entry period to give enough time to disarm the system z After the delay period is expired and no correct PIN code is entered to disarm the s...

Страница 24: ...ctor P for Away Entry PIR Detector StepB8 Use the S T keys to make your selection and confirm by pressing OK key You are now invited to give a name or location description to the device to help unders...

Страница 25: ...s to Device menu Other Devices For Smoke Detector Remote Keypad Water Sensor and Night Switch no further option needs to be specified hence after it is detected a zone is assigned and the zone name en...

Страница 26: ...ng OK key The screen will show Z o n e T y p e O k D C B a c k d o o r E Step3A Press OK key to confirm The next screen will ask if you want to change the name P r o g r a m N a me B a c k d o o r Ste...

Страница 27: ...xiliary devices Before adding these auxilary devices any least one other type of device must be learnt in already e g a Door Contact or PIR but not Siren Bell Box or PSS To program these auxiliary dev...

Страница 28: ...irmation where beeps are emitted from the Siren to validate that the system has been armed and disarmed z Disable the Siren Confirmation by selecting Confirmation Off and press OK key z Enable the Sir...

Страница 29: ...larm is restored the Power Switch will turn off 2 6 SMS Editor For sending a SMS alarm reporting to your mobile phone edit your SMS message by selecting SMS Editor in Programming Main menu E d i t S c...

Страница 30: ...your local Telecom provider for the correct format Or follow the steps below for checking your phone number format and setting the system to correct the format Step 1 Remove the SIM card from the Pane...

Страница 31: ...S i g n a l G S M R S S I 7 2 10 Walk Test z When Walk Test is selected the Green Yellow LED s will flash 3 times with 3 beeps and the following two test patterns are displayed for 2 sec each z Then t...

Страница 32: ...essage saved the screen will display SMS for SMS message reading If you press key while the Alarm off is displayed a Enter Code promp screen will be displayed After you enter your pin Code the above s...

Страница 33: ...the system please see the section Forced Arming below 3 3 Forced Arming z While you try to arm the system by entering the PIN Code if there is any fault situation has occurred before the display will...

Страница 34: ...lowing the Steps described above to execute Forced Arming 3 4 Disarm Alarm off mode Disarming the system To disarm the system If the system is in either the Away Arm mode or Home Arm mode Alarm ON ent...

Страница 35: ...Or you can do forced arming to enter Home mode compulsorily Please follow the instructions described in Forced Arming in Section 3 3 3 6 Partial By pass Arm Mode The Partial By pass Arm mode allows th...

Страница 36: ...ssed then the Contorl Panel will not respond to its triggering in Arm mode The by pass setting is effective for only one time once the system is disarmed the by pass setting is cleared automatically W...

Страница 37: ...nse Instant Burglar Alarm Start Entry Timer No Response No Response No Response Delay D No Response Instant Burglar Alarm Instant Burglar Alarm No Response No Response No Response Entry E Door Chime S...

Страница 38: ...ns to Alarm off N NO OT TE E Press key or no key is pressed within 5 sec the screen returns to 1st device display You can repeat from the beginning to view the alarm event one more time No alarm repor...

Страница 39: ...displayed then the screen returns to Alarm off 3 9 Event Log The alarm log memorises the last 20 system events including 9 All Alarm Events with Device ID 9 All Fault Warning Events 9 All Arming And D...

Страница 40: ...arning z This is to warn the user that an alarm report to the Emergency Phone Numbers is about to be made z When a zone that is not programmed for delay is violated during the Entry Delay or the corre...

Страница 41: ...emote Keypad Water Sensor Remote Controller or Smoke Sensor is low a Sensor Low Battery message will be detected z Sensor out of order The PIR Sensor Door Contact Water Sensor and Smoke Detector will...

Страница 42: ...move the cursor downwards or upwards The screen is also scrolled down or up respectively Step 5 After viewing all the fault events press key a prompt message is displayed C l e a r F a u l t D s p O...

Страница 43: ...on the panel will report the fault event by SMS to the first telephone number in all modes Sensor Sabotaged If the Tamper switch on the PIR Sensor Door Contact Remote Keypad or Bell Box BX 8 is trigge...

Страница 44: ...ontact triggered DC w Zone Name open PIR triggered IR w Zone Name Active 3 13 Remote Commanding The Unit can be controlled by Remote Control Commands sent via SMS messages 3 13 1 From Regular Phone Li...

Страница 45: ...1 51199 8th Power Switch Open for 1 Hour to 99 Hours N NO OT TE E 5 digit Control Command Format C C C D D The Number of the Power Switch Open period for hour CCC The Number of the Power Switch E g 51...

Страница 46: ...h 1 for 1 Hour and than turn off without a confirmation SMS back to your mobile phone The format is J O Y 1 2 3 4 5 1 1 0 1 The programmed SMS keyword User PIN Code Power Switch Number Time N NO OT TE...

Страница 47: ...all will automatically hang up Acknowledging with signal 0 If the recipient presses 0 on his phone set as the acknowledging signal The Control Panel will then take the following actions 9 The Control...

Страница 48: ...nter Code will be displayed 4 Enter the following keys sequence STSTSTST OK key 5 Press the key 6 All programmed parameters are reset to factory default setting 7 If more than 17 incorrect keys entere...