12
2.3.4. Master Code
z
Master Code is used for accessing the
Programming mode and it is set to
1111
as
factory default. Before you set your own
Master PIN code,
1111
has to be keyed in
every time it is required.
z
To set your Master Code, follow the same
steps as in setting the
Duress Code
described above.
To Edit Master Code
After the Master Code is programmed, it can
be edited by following the same steps as in
editing the Duress Code described above.
<
<
N
N
O
O
T
T
E
E
>
>
)
The Master code can not be
deactivated (same as the User #1 PIN
Code).
)
The Master Code is used only when
you enter the Programming mode.
In
other cases, only PIN Code should be
entered.
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
When entering the following individual setting
screens, the value displayed on the screen is
the current setting of each item.
If it is not necessary to change the current
setting, just press key to escape.
2.3.5. A. Entry Time (Away Entry Time)
When Door Contact (DC) or PIR Detector (IR)
is set as
Entry / Away Entry
attribute, the
system gets into counting down period (Away
entry timer) while the DC or IR is triggered
under Away arm mode.
During the counting down period, it is allowed
to use correct PIN code to disarm the alarm
and the alarm reporting will not be sent. On the
other hand, if the correct PIN code has not
been entered within the period, Control Panel
raises an alarm and sends an alarm report.
z
Options available are
Disable
(alarm
immediately) ,
10 sec
,
20 sec
, up to
70
sec
in 10-sec increments.
z
Press
OK
on A. Entry Timer and the
following screen will be displayed:
A . E n t r y T i m e
2 0 s e c . (
Λ
V O K )
z
20 sec. is set as factory default.
2.3.6. A. Exit Time (Away Exit Time)
While the system gets into Away arm mode by
Control Panel, Remote Controller (RC) or
Remote Keypad (KP), an Away exit timer starts
counting down.
During the counting down period, pressing the
Arm Button of the RC can restart the counting.
In addition, it is allowed to use correct PIN
code or press Disarm Button of the RC to stop
the counting and return to Alarm off mode.
z
Options available are
Disable
(exit timer
prohibited),
10 sec
,
20 sec
up to
70 sec
in
10-sec increments.
A . E x i t T
i m e
3 0 s e c . (
Λ
V O K )
z
30 sec. is set as factory default.
2.3.7. H. Entry Time (Home Entry Time)
When Door Contact (DC) or PIR Detector (IR)
is set as
Entry / Home Access
attribute, the
system gets into counting down period (Home
entry timer) while the DC or IR is triggered
under Home arm mode.
During the counting down period, it is allowed
to use correct PIN code to disarm the alarm
and the alarm reporting will not be sent. On the
other hand, if the correct PIN code has not
been entered within the period, Control Panel
raises an alarm and sends an alarm report.
z
Options available are
Disable
(alarm
immediately) ,
10 sec
,
20 sec
, up to
70
sec
in 10-sec increments.
H . E n t r y T i m e
2 0 s e c . (
Λ
V O K )
z
20 sec. is set as factory default.