Page 8
4990497003 Date: 11/2016
TR20 Installation, Operating & Maintenance Manual
3.3
Mounting
The TR20 should be installed vertically utilising all three mounting feet on one side of
the machine. The drive direction is specific to machine and is shown on the machine
itself (arrow indicating rotation next to input shaft). Additionally, the machine has
discharge flanges on both sides and above.
The input drive rotation and air path possibilities are shown below.
Installation
Figure 4. Mounting & Drive options
An incorrect drive rotation will
damage the compressor.
CAUTION
Outlet
Inlet
The basic TR20 compressor should be installed/mounted (using the M16 fittings
supplied in the machine mounting kit) as shown in fig. 5.
All M16 Grade 8.8 mounting nuts/bolts should be applied at a torque setting
of 225Nm.
Loctite 270 should also be applied
to secure the M16 mounting
studs into the TR20 feet.
NOTE
The compressor has three
mounting feet on each side
of the machine and should be
mounted using all 3 feet on
one side only.
NOTE
Rear CW
Rear ACW
Inlet on
either side,
3 outlet options