Leak detector Vakumatik IVF R34
7. Instructions for assembly
7.1.
General information / Assembly site
- The leak detector may only be assembled outside an ex-zone.
- The conditions for use have to be observed as stated in section 5.
- The maximum ambient temperature (see section 3) must not exceed.
- The leak detector should be assembled in a closed, dry and frost-free room, if
possible.
- The leak detector and the mounting material provided in the scope of delivery should be
mounted to a wall or mounting plate easily accessible, visible and, if possible, at eye level.
Hole separation 156 mm (drill template included in the package). Cover screw domes inside
the bottom part of the housing with protective caps (included in separate package).
- The lateral wall clearance of the air vents must be at least 3 cm.
- The leak detector must be assembled such that it is not subjected to direct sunlight or direct
heat.
- If for structural reasons the leak detector must be assembled outside of closed and dry
rooms, the leak detector must be installed into a weather-resistant protective housing (IP55,
available as accessory from the manufacturer) and equipped with an additional exterior
alarm.
- If ambient temperatures of below -5°C are expected at the assembly site, an additional
heater with thermostat must be installed (special equipment).
7.2.
Assembly of the liquid barrier (9)
- Prior to installing the liquid barrier, check its float
gauge seal for cleanliness.
- A liquid barrier and a condensate vessel (10), see
accessories, should be installed near by the
container's suction pipe nozzles.
7.3.
Assembly of the Connecting pipes (6,7,8)
- Ensure proper allocation of the suction, measuring
and exhaust line at the leak detector and the tank
(see service flap).
-
Connecting lines must be color-coded: suction line
(6) = white, measuring line (7) = red, exhaust line (8)
= green.
- Connecting lines between leak detector and tank
must be equipped with PVC hoses NW 6 (6x2 mm)
or similar, ensure stability.
- Do not fold or pinch connecting lines.
Ø 6mm
Ø 4mm
12