Minimum – Maximum Operating Conditions

RNC25

RNC35

RNC50

RNC75

RNC100

Min.-Max. Inlet Air Pressure (compressed air at inlet to dryer)

30 psig (2.1 kgf/cm

2

) - 232 psig (16.3 kgf/cm

2

)

Max. Inlet Air Temp. (compressed air at inlet to dryer)

110

°

F

Min.-Max. Ambient Temperature

Air-cooled 45

°

F (7

°

C) - 110

°

F (43

°

C)

Refrigeration System Data

Compressor Type

Hermetic - Resistance Start, Induction Run - Non-Cycling

Refrigeration Compressor Horsepower

1/6

1/5

1/4

1/3

1/2

BTU/HR – Refrigeration Only

@ 35

°

F Evaporator & 100

°

F Ambient                               

60 Hz / 50 Hz

1010 / 842

1380 / 1150

2160 / 1800

2780 / 2317

4430 / 3692

Refrigerant Type

 R-134a

R-134a

R-134a

R-134a

R-134a

Refrigerant Charge

See dryer serial number tag

Suction Pressure Setting (controlled by hot gas by-pass valve)

31.5 psig

31.5 psig

31.5 psig

31.5 psig

31.5 psig

Condenser Fan Switch Setting (in-out) (psig)

NA

NA

NA

NA

NA

Air Flow Across Condenser (cfm)                                     

 60 Hz / 50 Hz

 105 / 98

235 / 196

275 / 229

220 / 183

350 / 292

Electrical

Nominal Voltages

115/1/60

Max.- Min. Voltage

127-104

127-104

127-104

127-104

127-104

Rated Load Amps

3.4

3.9

5.9

7.4

10.3

Locked Rotor Amps

18.0

22.0

28.0

35.0

48.0

Minimum Circuit Ampacity

4.0

4.7

7.3

9.1

12.4

Branch Circuit Fuse Size (amps)

15

15

15

15

20

Watts @ 35

°

F Evaporator & 100

°

F Ambient

280

290

465

600

815

    Overload

Thermal & Current (Auto reset)

Nominal Voltages

208-230/1/60

Max.-Min. Voltage

253-187

253-187

253-187

253-198

253-187

Rated Load Amps

1.8

2.1

3.0

4.1

5.1

Locked Rotor Amps

8.5

13.7

14.4

19.0

23.0

Minimum Circuit Ampacity

2.2

2.6

3.7

5.1

5.2

Branch Circuit Fuse Size (amps)

15

15

15

15

15

Watts @ 35

°

F Evaporator & 100

°

F Ambient

280

290

470

600

815

Overload

 Thermal & Current (Auto reset)

Nominal Voltages

220-240/1/50

Max.-Min. Voltage

264-198

264-198

264-198

264-198

264-198

Rated Load Amps

1.6

1.8

2.6

3.5

4.2

Locked Rotor Amps

8.7

10.7

14.5

15.2

21.0

Minimum Circuit Ampacity

2.0

2.2

3.2

4.4

5.2

Branch Circuit Fuse Size (amps)

15

15

15

15

15

Watts @ 35

°

F Evaporator & 100

°

F Ambient

223

257

395

507

669

Overload

Thermal & Current (Auto reset)

ENGINEERING DATA

Содержание RNC25

Страница 1: ...DELS RNC25 RNC35 RNC50 RNC75 RNC100 CONTENTS GENERAL SAFETY INFORMATION 2 RECEIVING MOVING UNPACKING 2 1 0 INSTALLATION 3 2 0 OPERATION 4 3 0 MAINTENANCE 6 SIZING 6 ENGINEERING DATA 7 ELECTRICAL SCHEM...

Страница 2: ...evidence of loss or damage at time of delivery to you insist that a notation of this loss or damage be made on the delivery receipt by the carrier s agent B UNPACKING Check for Concealed Loss or Dama...

Страница 3: ...r installation Standard units are designed for indoor installation Contact manufacturer if installing outdoors 1 2 Mounting Mount the dryer on a level solid surface Holes are provided in the dryer bas...

Страница 4: ...ranty 1 5 Moisture separator A Separator and Oil Removal Filter where applicable has an internal drain which automatically discharges collected condensate It may be desirable to pipe the condensate fr...

Страница 5: ...2 Where the dryer is consistently operating at less than maximum capacity it may be possible to increase the LED set point to minimize air loss Discretionary adjustments to the dryer should only be m...

Страница 6: ...d drain mechanism annually To facilitate service maintenance kits are available Please refer to page 11 3 0 Maintenance Sizing Determining dryer capacity at actual operating conditions To determine th...

Страница 7: ...29 220 183 350 292 Electrical Nominal Voltages 115 1 60 Max Min Voltage 127 104 127 104 127 104 127 104 127 104 Rated Load Amps 3 4 3 9 5 9 7 4 10 3 Locked Rotor Amps 18 0 22 0 28 0 35 0 48 0 Minimum...

Страница 8: ...load TB Terminal Block CAP Start Capacitor SR Start Relay DRN1 Drain Solenoid STD IC2 MTR Compressor DRN2 Drain Solenoid IC2 Oil Coalescing Option FM Fan Motor TC1 Temperature Sensor Optional Notes 1...

Страница 9: ...G 18 3 16 18 3 16 18 3 16 20 11 16 20 11 16 H 21 3 16 21 3 16 21 3 16 24 3 16 24 3 16 I 18 1 2 18 1 2 18 1 2 24 24 J 16 1 2 16 1 2 16 1 2 21 13 16 21 13 16 Inlet Outlet Connections 1 2 MPT 1 2 MPT 1 2...

Страница 10: ...gh air outlet temperature 2 Refrigeration system not func tioning properly resulting in high air outlet temperature 3 Dryer is running with no load a Power failure b Line disconnect switch open c Blow...

Страница 11: ...0 120 5 G4130 120 8 G4130 120 9 G4130 121 11 G4130 121 9 G4130 121 9 G4130 122 10 G4130 122 11 G4130 122 15 Compressor Only G4130 108 34 G4130 108 61 G4130 108 35 G4130 108 38 G4130 108 39 G4130 108 4...

Страница 12: ...T OR ITS NEGLIGENCE IN WHATEVER MANNER INCLUDING DESIGN MANUFACTURE OR INSPECTION OF THE EQUIPMENT OR ITS FAILURE TO DISCOVER REPORT REPAIR OR MODIFY LATENT DEFECTS INHERENT THEREIN THE MANUFACTURER H...

Отзывы: