Gardner Denver RNC25 Скачать руководство пользователя страница 11

 11

75

100

PARTS

115/1/60

208-230/1/60

220-240/1/50

115/1/60

208-230/1/60

220-240/1/50

DESCRIPTION

100/1/50

100/1/50

Condensing Unit (Air-cooled) G4130-122-12

G4130-122-13

G4130-122-14

G4130-123-12

G4130-123-13

G4130-123-14

Compressor (Only)

G4130-108-44

G4130-108-45

G4130-108-46

G4130-108-47

G4130-108-48

G4130-108-49

Overload

G5925-578-7

G5925-578-8

G5925-578-9

G5925-578-10

G5925-578-11

G5925-578-12

Start Relay

G5945-683-7

G5945-683-8

G5945-683-9

G5945-683-10

G5945-683-11

G5945-683-12

Start Capacitor

N/A

G5910-103-26

G5910-103-27

G5910-103-28

G5910-103-29

G5910-103-29

Fan Motor

G6105-238-31

G6105-238-32

G6105-238-32

G6105-238-33

G6105-238-34

G6105-238-34

Fan Blade

G4140-227-19

G4140-227-25

G4140-227-25

G4140-227-20

G4140-227-20

G4140-227-20

Hot Gas By-Pass Valve

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

Condenser (Air Cooled)

G4130-111-20

G4130-111-20

G4130-111-20

G4130-111-21

G4130-111-21

G4130-111-21

Dryer

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

Fan Pressure Switch

N/A

N/A

N/A

N/A

N/A

N/A

Contactor

N/A

N/A

N/A

N/A

N/A

N/A

By-Pass Valve Strainer

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

On-Off Switch

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

High Temperature Sensor

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

Digital PC Board (IC 1-0)
w/ high temp-sensor

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

25

                                                      35

50

PARTS

115/1/60

208-230/1/60

220-240/1/50

115/1/60

208-230/1/60

220-240/1/50

115/1/60

208-230/1/60

220-240/1/50

DESCRIPTION

100/1/50

100/1/50

100/1/50

Condensing Unit (Air-cooled) G4130-120-5

G4130-120-8

G4130-120-9

G4130-121-11

G4130-121-9

G4130-121-9

G4130-122-10

G4130-122-11

G4130-122-15

Compressor (Only)

G4130-108-34

G4130-108-61

G4130-108-35

G4130-108-38

G4130-108-39

G4130-108-40

G4130-108-41

G4130-108-42

G4130-108-43

Overload

G5925-570-2

G5925-578-24

G5925-570-3

G5925-578-1

G5925-578-2

G5925-578-3

G5925-578-4

G5925-578-5

G5925-578-5

Start Relay

G5945-655-5

G5945-683-24

G5945-655-6

G5945-683-1

G5945-683-2

G5945-683-3

G5945-683-4

G5945-683-5

G5945-683-5

Start Capacitor

N/A

N/A

N/A

N/A

N/A

N/A

N/A

G5910-103-23

N/A

Fan Motor

G6105-239-1

G6105-237-4

G6105-237-4

G6105-238-27

G6105-238-28

G6105-238-28

G6105-238-29

G6105-238-30

G6105-238-30

Fan Blade

G4140-228-2

G4140-228-2

G4140-228-2

G4140-227-17

G4140-227-17

G4140-227-17

G4140-227-18

G4140-227-18

G4140-227-18

Hot Gas By-Pass Valve

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

G9802-1

Condenser (Air Cooled)

G4130-110-26

G4130-110-26

G4130-110-26

G4130-111-18

G4130-111-18

G4130-111-18

G4130-111-19

G4130-111-19

G4130-111-19

Dryer

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

G4130-165-14

By-Pass Valve Strainer

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

G4130-701-8

On-Off Switch

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

G6110-706-13

High Temperature Sensor

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

G6150-333-2

Digital PC Board (IC 1-0)
w/ high temp-sensor

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

G5945-576-7

PARTS LIST

Model

RNC25

RNC35

RNC50

RNC75

RNC100

Standard

RNCMK2

RNCMK2

RNCMK3

RNCMK4

RNCMK4

With Optional Cold Coaleser RNCMK12

RNCMK12

RNCMK13

RNCMK14

RNCMK14

Maintenance Kits

Содержание RNC25

Страница 1: ...DELS RNC25 RNC35 RNC50 RNC75 RNC100 CONTENTS GENERAL SAFETY INFORMATION 2 RECEIVING MOVING UNPACKING 2 1 0 INSTALLATION 3 2 0 OPERATION 4 3 0 MAINTENANCE 6 SIZING 6 ENGINEERING DATA 7 ELECTRICAL SCHEM...

Страница 2: ...evidence of loss or damage at time of delivery to you insist that a notation of this loss or damage be made on the delivery receipt by the carrier s agent B UNPACKING Check for Concealed Loss or Dama...

Страница 3: ...r installation Standard units are designed for indoor installation Contact manufacturer if installing outdoors 1 2 Mounting Mount the dryer on a level solid surface Holes are provided in the dryer bas...

Страница 4: ...ranty 1 5 Moisture separator A Separator and Oil Removal Filter where applicable has an internal drain which automatically discharges collected condensate It may be desirable to pipe the condensate fr...

Страница 5: ...2 Where the dryer is consistently operating at less than maximum capacity it may be possible to increase the LED set point to minimize air loss Discretionary adjustments to the dryer should only be m...

Страница 6: ...d drain mechanism annually To facilitate service maintenance kits are available Please refer to page 11 3 0 Maintenance Sizing Determining dryer capacity at actual operating conditions To determine th...

Страница 7: ...29 220 183 350 292 Electrical Nominal Voltages 115 1 60 Max Min Voltage 127 104 127 104 127 104 127 104 127 104 Rated Load Amps 3 4 3 9 5 9 7 4 10 3 Locked Rotor Amps 18 0 22 0 28 0 35 0 48 0 Minimum...

Страница 8: ...load TB Terminal Block CAP Start Capacitor SR Start Relay DRN1 Drain Solenoid STD IC2 MTR Compressor DRN2 Drain Solenoid IC2 Oil Coalescing Option FM Fan Motor TC1 Temperature Sensor Optional Notes 1...

Страница 9: ...G 18 3 16 18 3 16 18 3 16 20 11 16 20 11 16 H 21 3 16 21 3 16 21 3 16 24 3 16 24 3 16 I 18 1 2 18 1 2 18 1 2 24 24 J 16 1 2 16 1 2 16 1 2 21 13 16 21 13 16 Inlet Outlet Connections 1 2 MPT 1 2 MPT 1 2...

Страница 10: ...gh air outlet temperature 2 Refrigeration system not func tioning properly resulting in high air outlet temperature 3 Dryer is running with no load a Power failure b Line disconnect switch open c Blow...

Страница 11: ...0 120 5 G4130 120 8 G4130 120 9 G4130 121 11 G4130 121 9 G4130 121 9 G4130 122 10 G4130 122 11 G4130 122 15 Compressor Only G4130 108 34 G4130 108 61 G4130 108 35 G4130 108 38 G4130 108 39 G4130 108 4...

Страница 12: ...T OR ITS NEGLIGENCE IN WHATEVER MANNER INCLUDING DESIGN MANUFACTURE OR INSPECTION OF THE EQUIPMENT OR ITS FAILURE TO DISCOVER REPORT REPAIR OR MODIFY LATENT DEFECTS INHERENT THEREIN THE MANUFACTURER H...

Отзывы: