Gardner Denver
3 Control panel and display
11
1
2
4
5
6
7
8
9
10
11
12
13
14
3
SM 1760_DH
3.5 Pictogram
page
Home
Fig. 3 Pictogram page
Home
(
-Version shown,
-
Version similar)
1) Air
filter
2) Discharge
temperature
Compressed air temperature measured after screw
air end.
3) Discharge
pressure
The pressure measured in the pressure tank.
4) Status indicator – combined minimum
pressure/non-return valve
Indicates Open when the machine is delivering air.
Indicates Closed when the machine is not
delivering air.
5) Air
delivery
The arrow symbol flashes when machine is
delivering air; it is invisible when the machine is not
delivering air.
6) Water level, maximum
7) Current remaining time to water change
Indicates the remaining time to the next water
change.
8) Water change symbol
Flashes when the water change stage is active.
9) Water level, minimum
10) Pressure tank
11) Screw air end
12) Main drive motor
13) Motor speed
Current motor speed in rpm shown below in a
graphic display. The left side of the graphic
represents 0 rpm. The right side represents the
maximum motor speed.
Note
The minimum and maximum motor speeds are
dynamically calculated and may change depending on
the target pressure selected and the actual measured
line pressure.
14) Minimum motor speed mark
3.6
Cleaning the touch screen
1) Switch off the compressor and isolate it from the
power supply. The touch screen must be off.
2) Use a soft and slightly moistened cloth to clean the
touch screen without excessive pressure.
Caution
Do not wipe the screen with any corrosive liquid or
rough objects.
If necessary, a fat-dissolving dish washing liquid or
alcohol can be used.
VS
FS
VS
VS
VS