SB-7-622 Page 16
BLOWER STARTUP CHECKLIST
This startup procedure should be followed during the initial installation and after any shutdown periods or after the
blower has been worked on or moved to new location. It is suggested that the steps be followed in sequence and
checked off (
√) in the boxes provided.
1.
Check the unit and all piping for foreign material and clean if required.
2.
Check the flatness of the feet and the alignment of the drive. Feet that are bolted down in a bind
can cause housing distortion and internal rubbing. Misaligned V-drives can cause the rotors to
rub against the headplates and cause a reduction in the volumetric efficiency of the unit.
Misaligned couplings can ruin bearings.
3.
If the blower is V-belt driven, check the belt tension and alignment. Over-tensioned belts create
heavy bearing/shaft loads which lead to premature failure.
4.
Be sure adequate drive guards are in place to protect the operator from severe personal injury
and incidental contact.
5.
Check the unit for proper lubrication. Proper oil level cannot be over-emphasized. Too little oil
will ruin bearings and gears. Too much oil will cause overheating and can ruin gears and cause
other damage. Insure that grease lubricated bearings are properly lubricated.
6.
With motor electrical power locked out and disconnected, turn the drive shaft by hand to be
certain the impellers do not bind.
7.
“Jog” the unit with the motor a few times to check that rotation is in the proper direction, and to be
certain it turns freely and smoothly.
8.
The internal surfaces of all Sutorbilt units are mist sprayed with a rust preventive to protect the
machine during the shipping and installation period. This film should be removed upon initial
startup.
9.
Start the unit and operate 15 minutes at no load. During this time, check for hot spots and other
indications of interference.
10.
Apply the load and observe the operation of the unit for one hour. Check frequently during the
first day of operation.
11.
If malfunctions occur, do not continue to operate. Problems such as knocking rotors can cause
serious damage if the unit is operated without correction.
Содержание GAF P Series
Страница 19: ...SB 7 622 Page 18 SECTION 5 MAINTENANCE FIGURE 5 1 PULLER PLATE SK2154...
Страница 20: ...SB 7 622 Page 19 FIGURE 5 2 GEAR DRIVEN SK2150...
Страница 21: ...SB 7 622 Page 20 FIGURE 5 3 MECHANICAL SEAL INSTALLATION TOOL SK2152...
Страница 22: ...SB 7 622 Page 21 FIGURE 5 1 BEARING PRESS TOOL MECHANCIAL SEAL UNITS SK2156 FIGURE 5 4...
Страница 33: ...SB 7 622 Page 32 SECTION 8 PARTS LIST 300GAF810 B Ref Drawing...
Страница 35: ...SB 7 622 Page 34 300GAG810 A Ref Drawing...
Страница 37: ...SB 7 622 Page 36 300GAH810 A Ref Drawing...
Страница 39: ...SB 7 622 Page 38...