9. Maintenance
- 52 –
9. Maintenance
9.4.2.2
Models 590
through 5400
•
Isolate dryer from air supply
•
De-pressurize dryer by running dryer and allowing system
pressure to purge to atmosphere. Loss of pilot pressure
will eventually prevent purge/repressurization valves from
opening. Remaining pressure can be vented to
atmosphere through the manual drain on the pilot air
filter. The system must be fully de-pressurized before
removing the bowl.
•
Remove the filter bowl by pushing up, turning
counterclockwise and then pulling straight down.
•
Clean the filter bowl.
•
Replace the element – Pull off the old element and
discard. Make certain o-ring inside top of replacement
element is lubricated and in place and then push element
onto filter head.
•
Clean and lubricate o-ring at top of bowl and reassemble
in reverse order.
NOTE: Wave spring ends should be pointed down to prevent
the wave spring from interfering with reassembly.
Содержание DGH Series
Страница 12: ...4 Installation 12 4 Installation Figure 4 3 continued on next page 590 5400 SCFM General Arrangement...
Страница 22: ...6 Controller Level 1 22 6 Controller Level 1 Figure 6 2 Electrical Schematic Level 1 Controller...
Страница 23: ...6 Controller Level 1 23 6 Controller Level 1 Figure 6 3 Point to Point Connection Diagram Level 1 Controller...
Страница 24: ...6 Controller Level 1 24 6 Controller Level 1 Figure 6 4 continued on next page Panel Layouts Level 1 Controller...
Страница 39: ...7 Controller Level 2 39 7 Controller Level 2 Figure 7 2 Electrical Schematic Level 2 Controller...
Страница 42: ...7 Controller Level 2 42 7 Controller Level 2 Figure 7 4 continued on next page Panel Layout Level 2 Controller...