13-21-608 Page 18
DISCHARGE SERVICE LINE
- The discharge service line connection on both water-cooled and air-
cooled units is made at the right hand corner of the unit, viewed from the opposite end from control panel
side. When connecting two or more GD rotary screw units on a common manifold, each unit is isolated
by the check valve in the unit discharge line. If a Gardner Denver rotary screw unit is connected to
another compressor on a common manifold be sure the other compressor has a check valve in the line
between the machine and the manifold. If a rotary screw and a reciprocating compressor are connected
together on a common manifold, an air receiver must be located between the two units.
Discharge air used for breathing will cause severe injury or death.
Consult filtration specialists for additional filtration and treatment equipment to
meet health and safety standards.
BLOWDOWN VALVE PIPING
-
The blowdown valve is piped back into the airend between the inlet valve
and air filter.
HEAT EXCHANGER
Water Temperature to Heat
Exchanger
(gpm)
Maximum
Water Flow
(gpm) **
Approximate Water
Pressure Drop @ 90
°
F
Water Temperature
(psi)
HP
Model
60
°
F
70
°
F
80
°
F
90
°
F
125 HP
EAQ99W
12.1
15.2
20.2
30.3
40.0
4.0
125 HP
EBQ99R
11.3
14.1
18.9
28.3
40.0
4.0
150 HP
EAQ99W
14.6
18.2
24.3
36.4
40.0
4.0
150 HP
EBQ99R
13.1
16.3
21.8
32.7
40.0
4.5
200 HP
EAQ99W
18.3
22.8
30.4
45.5
110.0
5.0
200 HP
EAU99Y
18.9
23.6
31.5
47.3
110.0
5.0
200 HP
EBU99F
18.9
23.6
31.5
47.3
110.0
5.0
200 HP
EBQ99R
16.4
20.4
27.3
40.9
110.0
5.0
* 80
°
F Maximum Water Temperature when aftercooler & oil cooler are piped in series (std).
** Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
Содержание AirSmart ELECTRA-SAVER
Страница 12: ...13 21 608 Page 11 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 200EDM797 A Ref Drawing...
Страница 13: ...13 21 608 Page 12 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 45: ...13 21 608 Page 44 Figure 4 14 WIRING DIAGRAM WYE DELTA 335EAQ546 A Ref Drawing Page 1 of 2...
Страница 46: ...13 21 608 Page 45 335EAQ546 A Ref Drawing Page 2 of 2...
Страница 47: ...13 21 608 Page 46 Figure 4 15 WIRING DIAGRAM LESS STARTER 336EAQ546 A Ref Drawing Page 1 of 3...
Страница 48: ...13 21 608 Page 47 336EAQ546 A Ref Drawing Page 2 of 3...
Страница 49: ...13 21 608 Page 48 336EAQ546 A Ref Drawing Page 3 of 3...
Страница 53: ...13 21 608 Page 52 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...
Страница 78: ......
Страница 79: ...NOTES...