13-21-608 Page 26
The compressor starts and stops automatically. Automatic restarting can
cause injury or death. Open, lockout and tagout main disconnect and any other
circuits before servicing the unit.
STARTING THE UNIT
- Observe the following starting procedures.
Unit Cold
- If the unit is a water-cooled heat exchanger model, open any manual water inlet valves wide
open. Start the unit by pushing either the
“CONSTANT RUN” button or one of the “AUTO” buttons. Since
the unit is equipped with a minimum (65 psig, 4.5 bar) pressure discharge valve, no special procedure to
maintain unit reservoir pressure is required.
Unit Hot
- No warm-up period is required. If the unit is a water-cooled heat exchanger model, open any
manual water inlet valves wide open. Start the unit by pushing either the
“CONSTANT RUN” button or
one of the
“AUTO” buttons.
DAILY CHECK
- Refer to Section 8,
“Maintenance Schedule,” page 73.
STOPPING THE UNIT
- Press
“STOP-RESET” button. The oil reservoir will automatically blow down as
the motor stops. If the unit is a water-cooled heat exchanger type, close any manual water inlet valves.
Содержание AirSmart ELECTRA-SAVER
Страница 12: ...13 21 608 Page 11 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 200EDM797 A Ref Drawing...
Страница 13: ...13 21 608 Page 12 Figure 1 6 AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 45: ...13 21 608 Page 44 Figure 4 14 WIRING DIAGRAM WYE DELTA 335EAQ546 A Ref Drawing Page 1 of 2...
Страница 46: ...13 21 608 Page 45 335EAQ546 A Ref Drawing Page 2 of 2...
Страница 47: ...13 21 608 Page 46 Figure 4 15 WIRING DIAGRAM LESS STARTER 336EAQ546 A Ref Drawing Page 1 of 3...
Страница 48: ...13 21 608 Page 47 336EAQ546 A Ref Drawing Page 2 of 3...
Страница 49: ...13 21 608 Page 48 336EAQ546 A Ref Drawing Page 3 of 3...
Страница 53: ...13 21 608 Page 52 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 203EDM797 A Ref Drawing...
Страница 78: ......
Страница 79: ...NOTES...