13-10-618 Page 61
If the leak develops through the packing, tighten the packing gland nut firmly with a wrench to reseat the
packing around the valve stem, then back off the nut until loose, and finally retighten the nut finger tight.
Tightening the packing nut too tight may cause erratic operation. An occasional drop of oil on the valve
stem at the packing nut will prolong packing life.
If valve malfunctions, check for bent or binding, paint or corrosion on valve stem, foreign material in valve,
erosion, or thermal system (capillary) failure. If foreign material or scale is likely, the use of a strainer in
the inlet water line is recommended.
WATER SHUTOFF VALVE - WATER-COOLED HEAT EXCHANGER (Optional Equipment)
(
Figure 5-3
,
page 48
)
- A magnetic solenoid-operated water shutoff valve rated at 150 psig (10.3 bar) water pressure
should be mounted in the water outlet line after the oil cooler. The valve should be wired into the
compressor control circuit so that the valve opens to allow water to flow any time the compressor is
running. When compressor stops under automatic control, or is shut off manually, the valve should close,
stopping water flow through the system. See Wiring Diagrams, pages 32 thru 35.
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
OIL RESERVOIR
- The oil reservoir-separator combines multiple functions into one vessel. The lower
half is the oil reservoir, providing oil storage capacity for the system and the top portion, a primary oil
separation means. The reservoir also provides limited air storage for control and gauge actuation.
Figure 5-11 – OIL SEPARATOR
211EAU797
(Ref. Drawing)
Содержание AirSmart EAU99T
Страница 13: ...13 10 618 Page 12 Figure 1 6 PACKAGE AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 39: ...13 10 618 Page 38 Figure 4 8 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 B Ref Drawing...
Страница 42: ...13 10 618 Page 41 Figure 4 11 WIRING DIAGRAM WYE DELTA 329EAU546 A Ref Drawing Page 1 of 2...
Страница 43: ...13 10 618 Page 42 329EAU546 A Ref Drawing Page 2 of 2...
Страница 44: ...13 10 618 Page 43 Figure 4 12 WIRING DIAGRAM WYE DELTA 330EAU546 A Ref Drawing Page 1 of 2...
Страница 45: ...13 10 618 Page 44 330EAU546 A Ref Drawing Page 2 of 2...
Страница 49: ...13 10 618 Page 48 Figure 5 3 FLOW DIAGRAM 210EAU797 B Ref Drawing...