13-10-618 Page 23
4.
Wipe lubrication fitting clean and add grease with a hand-operated grease gun. Only enough grease
should be added to replace the grease used by the bearing. Too much grease can be as harmful as
insufficient grease. The grease capacity should be about ½ full.
5.
Leave the relief plug temporarily off. Reconnect the unit and run for about 20 minutes to expel the
excess grease.
6.
Stop the unit. Replace the relief plug.
7.
Restart the unit.
Rotating machinery can cause injury or death. Open main disconnect, lockout
and tagout power supply to starter before working on the electric motor.
ELECTRIC MOTOR GREASE RECOMMENDATIONS (-30
°
C to 50
°
C)
MANUFACTURER
TRADE NAME
CHEVRON
SRI #2
SHELL
DOLIUM R
EXXON
UNIREX #2
EXXON
POLYREX
ELECTRIC MOTOR REGREASING INTERVAL
Type of
Service
Typical
Rating
Relubrication Interval
Standard
One or Two Shift Operation
Up to 150 HP (112 kW)
18 Months
Above 150 HP (112 kW)
12 Months
Severe
Continuous Operation
Up to 150 HP (112 kW)
9 Months
Above 150 HP (112 kW)
6 Months
Very Severe
Dirty Locations, High Ambient
Temperature
Up to 150 HP (112 kW)
4 Months
Above 150 HP (112 kW)
2 Months
Содержание AirSmart EAU99T
Страница 13: ...13 10 618 Page 12 Figure 1 6 PACKAGE AIR OIL FLOW DIAGRAM 202EDM797 Ref Drawing...
Страница 39: ...13 10 618 Page 38 Figure 4 8 CONTROL SCHEMATIC COMPRESSOR AT FULL LOAD 206EAU797 B Ref Drawing...
Страница 42: ...13 10 618 Page 41 Figure 4 11 WIRING DIAGRAM WYE DELTA 329EAU546 A Ref Drawing Page 1 of 2...
Страница 43: ...13 10 618 Page 42 329EAU546 A Ref Drawing Page 2 of 2...
Страница 44: ...13 10 618 Page 43 Figure 4 12 WIRING DIAGRAM WYE DELTA 330EAU546 A Ref Drawing Page 1 of 2...
Страница 45: ...13 10 618 Page 44 330EAU546 A Ref Drawing Page 2 of 2...
Страница 49: ...13 10 618 Page 48 Figure 5 3 FLOW DIAGRAM 210EAU797 B Ref Drawing...