IMPORTANT: RECEIVING INSTRUCTIONS 

Visually inspect all components for shipping damage.
If any shipping damage is found, notify carrier at once.

Shipping damage is NOT covered by warranty. The 
carrier is responsible for all repair or replacement
costs resulting from damage in shipment.

Do not use broken or damaged cable puller component parts.
Damaged parts can cause structural weakness resulting in failures
at loads below rated capacity.

CATALOG 

NUMBER

DESCRIPTION

CP8006

Brutus™ Power Puller – with 600’ rope; for 
exposed or concealed conduit (Wt: 495 lbs.). 
Includes metal case with casters (Cat. #CM16).

CATALOG 

NUMBER

DESCRIPTION

CP8003

Brutus™ Power Puller – with 300’ rope; for
exposed or concealed conduit (Wt: 440 lbs.). 
Includes metal case with casters (Cat. #CM16).

CATALOG 

NUMBER

DESCRIPTION

CP8000

Brutus™ Power Puller – for exposed or 
concealed conduit (Wt: 235 lbs.). 
Includes metal case with casters (Cat. #CM16).

CATALOG 

NUMBER

DESCRIPTION

CP8000D

Brutus™ Power Puller – for exposed conduit 
(Wt: 355 lbs.). Includes metal case with casters 
(Cat. #CM16).

Содержание CP800

Страница 1: ...se structural weakness resulting in failures at loads below rated capacity CATALOG NUMBER DESCRIPTION CP8006 Brutus Power Puller with 600 rope for exposed or concealed conduit Wt 495 lbs Includes meta...

Страница 2: ...instruction that applies to each unique situation Principles presented here provide as much general assistance as possible Assembly instructions are specific Follow them precisely to ensure safe relia...

Страница 3: ...er extension pulling down from box on ceiling Pulling from 90 connector to obtain leads long enough to complete connection in junction box Conduit frame adaptor and power head assembly chained separat...

Страница 4: ...onduit extension Conduit frame adapter chained to conduit pulling up Resting conduit frame adaptor on floor over conduit and pulling up Resting conduit frame adaptor on floor and blocks over conduit a...

Страница 5: ...operator cannot become entangled Never stand directly under a vertical pull Do not stand directly in front of a pull rope under tension The operator must stand at an angle to the capstan Keep all oth...

Страница 6: ...e Rope Reverse the rope end for end between uses Also alternate the lay of the rope around capstan and sheaves from job to job Repeated hauling of a line over a capstan in a counterclockwise direction...

Страница 7: ...ve chained to exposed conduit Power head assembly being attached to conduit frame adapter using two lock pins Pulling up cable with conduit frame adapter chained to exposed conduit mounted flush Condu...

Страница 8: ...lowing 26 pictures showing the versatility of and suggested applications for the GB Electrical Powered Cable Puller These same pictures are also on the inside cover of the metal storage case for ready...

Страница 9: ...le pull during which the load meter registers in the red zone Do not operate puller when pull requires more than 8 000 lbs of pulling force Cable puller and accessories are rated for a maximum of 8 00...

Страница 10: ...hing Slots Tighten with screwdriver shank adjustable wrench handle a piece of flat steel or hex socket wrench allen wrench Figure 3 Make sure that the links A are straight during installation Avoid si...

Страница 11: ...er is color coded as follows 0 to 4 000 lbs Green Band Most Average Pulls 4 000 to 8 000 lbs Yellow Band Heavy Pulls To avoid overheating the motor when making pulls in excess of 4 000 lbs stop the mo...

Страница 12: ...706 CP707 or CP708 Do not attach the coupling clamp to the outside of the conduit using chains or similar devices 2 The slots in the coupling frame are designed to engage the trunion studs on CP703 fr...

Страница 13: ...the power head CP800 on the conduit frame adaptor CP601 Position the power head on the frame and secure using two 8 inch long pins CP505 See figure 5 DANGER Figure 5 Be sure the mounting pins CP505 pa...

Страница 14: ...If power head is rotated pull rope must always be wound from narrow end toward wide end of capstan to prevent overlap Optional Mounting Position of CP800 Normal Mounting Position of CP800 8 Figure 6...

Страница 15: ...entire length of the frame adaptor opening Figure 8 2 Use of the CP703 pipe adaptor also requires the S8512 10 inch sheave for the rope to travel across The sheave must be mounted with one CP505 8 in...

Страница 16: ...rdered individually WARRANTY GB ELECTRICAL INC warrants its products against defects in workmanship and materials for 1 year from date of delivery to user Chain is not warranted Warranty does not cove...

Отзывы: