background image

2

!

!

DANGER

IMPORTANT - USER SAFETY AND PROTECTION: In setting up systems, take care to select the
proper components and design to insure appropriate integration with your operations and
existing equipment. Observe all safety measures to avoid the risk of personal injury and
property damage from your application or system.

GB ELECTRICAL CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY
UNSAFE USE, MAINTENANCE OR APPLICATION OF ITS PRODUCTS. Please contact GB
Electrical for guidance when you are in doubt as to the proper safety precautions to be taken
in designing and setting up your particular application.

INTRODUCTION

GB Electrical produces three different models of cable pullers. Each version uses the CP800 power
head assembly. Differences between models are based on the accessories included with each model
or the length of rope provided with the cable puller. Since the same CP800 power head is part of
each model, the instructions and safety information apply to all uses of GB powered cable pullers.

Cable pulling encounters a wide variety of situations and materials. Because of that variety, it is not
possible to provide instruction that applies to each unique situation. Principles presented here provide
as much general assistance as possible. Assembly instructions are specific. Follow them precisely to
ensure safe, reliable and effective cable puller installations.

All instructions are important, but safety is paramount during pulling. Safety alert symbols are located
throughout this manual, and a separate section is included to identify specific safety concepts.

Before operating the GB cable puller, read and understand this entire manual. If you do not
understand any area or subject, contact GB Electrical, Inc. at 1-414-352-4160 or 1-800-624-4320.
Ask for Technical Services.

SAFETY ALERT SYMBOLS

The symbol to the left is used in conjunction with a danger, warning or caution
statement. It alerts operators, supervisors and all personnel that safety
precautions are required during specific situations and under specific conditions.
Failure to comply with safety data could result in serious injury or death.

This symbol indicates a high probability that death, severe injury or
major property damage could result.

This symbol indicates serious but less probability that death,
severe bodily injury or major property damage could result.

This is a less serious alert but still demands attention to detail. It
indicates a hazard that may cause minor injuries.

Содержание CP800

Страница 1: ...se structural weakness resulting in failures at loads below rated capacity CATALOG NUMBER DESCRIPTION CP8006 Brutus Power Puller with 600 rope for exposed or concealed conduit Wt 495 lbs Includes meta...

Страница 2: ...instruction that applies to each unique situation Principles presented here provide as much general assistance as possible Assembly instructions are specific Follow them precisely to ensure safe relia...

Страница 3: ...er extension pulling down from box on ceiling Pulling from 90 connector to obtain leads long enough to complete connection in junction box Conduit frame adaptor and power head assembly chained separat...

Страница 4: ...onduit extension Conduit frame adapter chained to conduit pulling up Resting conduit frame adaptor on floor over conduit and pulling up Resting conduit frame adaptor on floor and blocks over conduit a...

Страница 5: ...operator cannot become entangled Never stand directly under a vertical pull Do not stand directly in front of a pull rope under tension The operator must stand at an angle to the capstan Keep all oth...

Страница 6: ...e Rope Reverse the rope end for end between uses Also alternate the lay of the rope around capstan and sheaves from job to job Repeated hauling of a line over a capstan in a counterclockwise direction...

Страница 7: ...ve chained to exposed conduit Power head assembly being attached to conduit frame adapter using two lock pins Pulling up cable with conduit frame adapter chained to exposed conduit mounted flush Condu...

Страница 8: ...lowing 26 pictures showing the versatility of and suggested applications for the GB Electrical Powered Cable Puller These same pictures are also on the inside cover of the metal storage case for ready...

Страница 9: ...le pull during which the load meter registers in the red zone Do not operate puller when pull requires more than 8 000 lbs of pulling force Cable puller and accessories are rated for a maximum of 8 00...

Страница 10: ...hing Slots Tighten with screwdriver shank adjustable wrench handle a piece of flat steel or hex socket wrench allen wrench Figure 3 Make sure that the links A are straight during installation Avoid si...

Страница 11: ...er is color coded as follows 0 to 4 000 lbs Green Band Most Average Pulls 4 000 to 8 000 lbs Yellow Band Heavy Pulls To avoid overheating the motor when making pulls in excess of 4 000 lbs stop the mo...

Страница 12: ...706 CP707 or CP708 Do not attach the coupling clamp to the outside of the conduit using chains or similar devices 2 The slots in the coupling frame are designed to engage the trunion studs on CP703 fr...

Страница 13: ...the power head CP800 on the conduit frame adaptor CP601 Position the power head on the frame and secure using two 8 inch long pins CP505 See figure 5 DANGER Figure 5 Be sure the mounting pins CP505 pa...

Страница 14: ...If power head is rotated pull rope must always be wound from narrow end toward wide end of capstan to prevent overlap Optional Mounting Position of CP800 Normal Mounting Position of CP800 8 Figure 6...

Страница 15: ...entire length of the frame adaptor opening Figure 8 2 Use of the CP703 pipe adaptor also requires the S8512 10 inch sheave for the rope to travel across The sheave must be mounted with one CP505 8 in...

Страница 16: ...rdered individually WARRANTY GB ELECTRICAL INC warrants its products against defects in workmanship and materials for 1 year from date of delivery to user Chain is not warranted Warranty does not cove...

Отзывы: