background image

13

GB

Risk of injury ! 

Pulling the cutting filament
manually out of the filament
cassette :

5

G

Only use original GARDENA Filament Cassettes. You can
order Replacement Filament Cassettes from your GARDENA
dealer or directly from the GARDENA Customer Service.

Filament Cassette for Turbotrimmer SmallCut 300 :

Art. 5306 

1. Unplug the mains plug.

2. Release the cassette cover

C

by pressing both locking clips

D

and remove the cover.

3. Remove the filament cassette

E

.

4. Remove any dirt.

5. Feed the cutting filament

5

of the new filament cassette

E

through the hole

F

and pull out about 10 cm.

6. Insert the filament cassette

E

.

Do not trap the cutting 

filament

5

when you do this.

7. Fit the cassette cover

C

so that you hear both locking 

clips

D

click into place.

v

If the cassette cover

C

cannot be touched down, turn the 

filament cassette 

E

to and fro, until the filament cassette

E

is completely in the filament cassette holder.

7. Troubleshooting 

Risk of injury from the cutting filament ! 

V

Always unplug the mains plug of the Turbotrimmer be-
fore troubleshooting.

A cutting filament that is too short or no longer extends auto-
matically when the trimmer is turned on can be pulled out 
manually.

1. Unplug the cable from the mains.

2. Hold the automatic slide feed

G

down with your hand and at

the same time pull on the cutting filament

5

.

If the cutting filament has disappeared into the filament cassette 
or if the automatic filament extension still doesn’t work after pulling
the cutting filament

5

it may be fused together in the filament 

cassette

E

.

1. Unplug the cable from the mains.

2. Remove the filament cassette

E

as described in 

6. Maintenance 

“Replacing the filament cassette”

.

3. Unwind the cutting filament

5

, clean the filament cassette

E

and the cutting filament

5

and wind the cutting filament

5

onto the cassette

E

once more.

4. Clean the automatic mechanism lever

G

.

The automatic lever

must move freely.

5. Insert the filament cassette again as described under 

6. Maintenance 

“Replacing the filament cassette”

.

Releasing a cutting filament
that has gone into the 
cassette or which has fused :

D

E

F

5

C

D

E

F

5

G

Содержание SmallCut 300

Страница 1: ...upe bordures NL Instructies voor gebruik Turbotrimmer S Bruksanvisning Turbotrimmer DK Brugsanvisning Turbotrimmer I Istruzioni per l uso Turbotrimmer E Manual de instrucciones Turbotrimmer P Instruções de utilização Turbotrimmer FIN Käyttöohje Turbotrimmeri N Bruksanvisning Turbotrimmer SmallCut 300 Art 8845 GARDENA ...

Страница 2: ...to Use Your GARDENA Turbotrimmer The GARDENA Turbotrimmer is designed for trimming and cutting areas of grass and lawns in private house and hobby gardens The Turbotrimmer must not be used in public facilities parks sports grounds next to roads or in agriculture or forestry For safety reasons the GARDENA Turbotrimmer must not be used for hedge trimming or for shredding for composting Contents 2 Sa...

Страница 3: ...ct your legs Keep your fingers and feet away from the cutting filament above all when starting work v Always ensure that you have a secure foothold whilst working v Keep the extension cable away from the area you are cutting Take extra care when walking backwards You may stumble v Only work in the daylight or when visibility is good Interrupting work v Never leave the Turbotrimmer unattended where...

Страница 4: ...ck to the handle 1 Insert the extension cable 6 into the cable lock 7 on the upper part of the handle 1 2 Plug the plug 8 of the trimmer into the socket 9 of the extension cable 3 Plug the extension cable into a 230 V mains power supply v Hold the trimmer by the top of the handle 1 and the additional handle so that the cutting head 2 is tilted slightly forward The cutting filament extends complete...

Страница 5: ... product must not be added to normal household waste It must be disposed of in line with local environmental regulations v Important Make sure that the unit is disposed of via your municipal recycling collection centre 6 Maintenance There is a risk of injury from the cutting filament V Always unplug the mains plug of the Turbotrimmer be fore carrying out maintenance work Risk of injury and risk of...

Страница 6: ...rom the cutting filament V Always unplug the mains plug of the Turbotrimmer be fore troubleshooting A cutting filament that is too short or no longer extends auto matically when the trimmer is turned on can be pulled out manually 1 Unplug the cable from the mains 2 Hold the automatic slide feed G down with your hand and at the same time pull on the cutting filament 5 If the cutting filament has di...

Страница 7: ...quency 230 V 50 60 Hz Filament thickness 1 5 mm Cutting width 230 mm Filament supply 10 m Filament feed Fully automatic Weight 1 8 kg Rpm of filament cassette 11 100 rpm Work area related emission characteristic value LpA 1 85 dB A Noise level LWA 2 measured 94 dB A guaranteed 96 dB A Hand arm vibration avhw 1 2 5 m s2 Measuring method according to 1 EN 786 2 directive 2000 14 EC 9 Service Warrant...

Страница 8: ...ntee does not affect the user s existing warranty claims against the dealer seller If a fault occurs with your Turbotrimmer please return the faulty unit together with a copy of the receipt and a description of the fault with postage paid to one of the GARDENA Service Centres listed on the back of these operating instructions ...

Страница 9: ...en om skadan beror på att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra än Original GARDENA reservdelar har använts Samma sak gäller för kompletteringsdelar och tillbehör K Produktansvar Vi gør udtrykkeligt opmærksom på at i henhold til produktansvarsloven er vi ikke ansvarlige for skader forårsaget af vores udstyr hvis det skyldes uautoriserede reparationer eller ...

Страница 10: ...met ons afgestemde verandering aan het apparaat verliest deze verklaring haar geldigheid S EU Tillverkarintyg Undertecknad firma GARDENA Manufacturing GmbH Hans Lorenser Str 40 D 89079 Ulm intygar härmed att nedan nämnda produkter överensstämmer med EU s direktiv EU s säkerhetsstandard och produktspecifikation Detta intyg upphör att gälla om produkten ändras utan vårt tillstånd K EU Overensstemmel...

Страница 11: ...al GmbH Hans Lorenser Straße 40 D 89079 Ulm vakuuttaa että allamainitut laitteet täyttävät tehtaaltamme läh tiessään yhdenmukaistettujen EY direktiivien EY turvallisuusstandardien ja tuotekohtaisten standardien vaatimukset Laitteisiin tehdyt muutokset joista ei ole sovittu kanssamme johtavat tämän vakuutuksen raukeamiseen n EU samsvarserklæring Den undertegnede GARDENA International GmbH Hans Lore...

Страница 12: ... gardena hu Iceland Ó Johnson Kaaber Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it Japan KAKUICHI Co Ltd Sumitomo Realty Development Kojimachi BLDG 8F 5 1 Nibanncyo Chiyoda ku Tokyo 102 0084 Phone 81 33 264 4721 m_ishihara kaku ...

Отзывы: