In garden ponds the density of fish stock per cubic metre is usually
higher than in natural ponds. As the fish usually also receive more
food than in their natural environment, the amount of pollution due
to excrement is very high.

Excess growth of algae, as well as the high level of pollution 
due to fish excrement causes a lack of oxygen in your pond; its 
biological balance has been disturbed.

Problem : the level of nutrients in your pond is too high.

The most effective solution to this problem is to decrease the 
level of nutrients available by means of a biological process and 
to remove excess nutrients while at the same time increasing the
oxygen supply.

The growth of algae can be restricted by installing a filter. Floating
substances (e.g. floating algae), which cause the water to be
murky, are filtered out and the water is purified. This helps the
pond to regain its biological balance. However, existing algae 
(e.g. thread algae) visible at the time of installation must be 
skimmed off (e.g. with the GARDENA combisystem Pond Net, 
Art. No. 7933).

Where possible, the filter should be kept in permanent operation
and not be allowed to dry out.

When newly installed, the UVC-Pressure Filter Set only reaches its
full biological cleaning effect after a few weeks. Extensive bacteria
activity only takes place from a temperature of + 10 °C or above.

High density of fish stock :

Level of nutrients :

Installing a filter :

Note :

2. Safety Instructions 

V

The safety instructions on the GARDENA UVC Pressure Filter Set must be followed !

WARNING ! 

V

Read the operating
instructions before
using the equipment 
for the first time !

DANGER ! 

V

Ultraviolet radiation.
Protect eyes from flash.

This radiation is harmful to eyes and skin.

Never operate the UV unit when the
housing has been removed.

Electrical safety :

DANGER ! Electric shock ! 

V

Disconnect the pump and the
UVC device from the power 
supply before carrying out work.

v

v

Inspect the equipment before use to 
ensure that the pump and the UVC unit,
especially the power cable and plug, are
undamaged.

Do not use a damaged UVC unit or pump.

Do not use the light if the connection lead,
glass tube or the housing of the UVC unit
appear to be defective.

If the pump or UVC unit is damaged, please
have them checked by our GARDENA Service
Centre or an authorised electrician.

The UVC-unit and the pump must be operated
via a residual-current device (FI-switch) with a
nominal fault current 

30 mA (DIN VDE 0100-

702 and 0100-738).

v

Please ask your electrician for his advice.

Содержание PF 10000 S

Страница 1: ...iltre pression UVC NL Instructies voor gebruik UVC drukfilterset S Bruksanvisning UVC tryckfilterset I Istruzioni per l uso Set filtro a pressione UVC E Manual de instrucciones Juego de filtros a pres...

Страница 2: ...Range of Uses forYour GARDENA UVC Pressure Filter Set The UVC Pressure Filter Set is intended for private use in domestic gardens and allotments and should only be used out of doors for cleaning gard...

Страница 3: ...t When newly installed the UVC Pressure Filter Set only reaches its full biological cleaning effect after a few weeks Extensive bacteria activity only takes place from a temperature of 10 C or above H...

Страница 4: ...ansformer v Please contact your electrician For Switzerland In Switzerland mobile appliances which are used outdoors must be connected via a residual current device Note Operation of the pressure filt...

Страница 5: ...s This promotes the growth of micro organisms which guarantee the conversion of ammonia into nitrate via nitrite nitrification Lava stone This supports the growth of anaerobic micro organisms which pr...

Страница 6: ...the surface of the pond When using a stream the maximum height must not be exceeded 1 Bury or position the pressure filter D securely at least 2 m away next to the garden pond and above the surface of...

Страница 7: ...nce DANGER Electric shock A v v Before undertaking maintenance unplug the UVC unit and the pump from the mains WARNING Danger of the container bursting A v v Do not connect the pressure filter to the...

Страница 8: ...ing water 7 Assemble the pressure filter again in reverse order Ensure that the O Ring O is sitting correctly 8 Start operation of the pressure filter again see 5 Initial Operation Operating the UVC P...

Страница 9: ...he UVC unit in reverse order DANGER Short circuit A v v The ring U must be screwed on firmly again to guarantee that the glass tube T is sealed During assembly ensure that the O Ring X on the glass tu...

Страница 10: ...res or an authorised repairer If any other faults arise please contact GARDENA Service 9 Accessories GARDENA 1 Hose for use as inflow Art 7831 Ribbed pond hoses or outflow hose 10 Technical Data PF 10...

Страница 11: ...d in keeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The wearing parts UVC bulb filter materials and...

Страница 12: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Страница 13: ...urit et autres r gles qui lui sont applicables dans le cadre de l Union europ enne Toute modification port e sur ce produit sans l accord express de GARDENA supprime la validit de ce certificat N EU o...

Страница 14: ...di rendimento Curva caracter stica de la bomba Caracter sticas de performance Ydelses karakteristika PF 10000 S Art 7872 Pumpen Kennlinie Performance characteristics Courbes de performance Prestatieg...

Страница 15: ...k ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it Japan K...

Отзывы: