background image

18

GB

Overwintering /
Storage :

We recommend that you lay the return flow in such a way that
the purified water is reintroduced indirectly e.g. via a short 
stream. This enriches the purified water with additional oxygen.

6. Putting out of Operation 

1. Before frost, remove the pump from the pond, remove the hose

from the pump and fully empty the UVC pressure filter.

2. Clean the UVC pressure filter thoroughly (see 

7. Maintenance

“ Removing fine dirt”

) and allow to dry.

3. Immerse the pump 

(without mains plug)

completely in a 

container filled with water.

4. Position the UVC pressure filter and pump in a place protected

from frost, and ensure that the mains plug of the UVC device
and pump are protected from moisture.

Store out of reach of children.

The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.

7. Maintenance 

DANGER ! Electric shock ! 

A

v

v

Before undertaking maintenance, unplug the 
UVC-unit and the pump from the mains ! 

WARNING ! Danger of the container bursting !  

A

v

v  

Do not connect the pressure filter to the 
domestic water supply ! 

Dirt indicator visible 

Dirt indicator not visible 

.

Flow 

.

No / insufficient flow 

.

Filter function O.K.

.

Filter soiled 

If the dirt indicator is not fully visible during operation indicating 
a low flow, the pressure filter must be cleaned. The mechanical
cleaning equipment simplifies the cleaning process.

1. Exchange the connecting hose 

1

and return hose 

C

and 

guide the return hose 

C

to the desired position.

2. Connect the pump to the power supply.

3. Pull the cleaning handle 

G

several times during operation 

and hold briefly. The filter sponges are squeezed and the 
dirt washed out.

4. If the water from the return hose 

C

is clear, switch off the pump.

5. Exchange the connecting hose 

1

and return hose 

C

again 

and guide the return hose 

C

back into the stream or pond.

Return flow tip :

Removal of severe soiling :

Disposal :

(in accordance with 
RL 2002 / 96 / EC)

G

1

G

C

Содержание PF 10000 S

Страница 1: ...iltre pression UVC NL Instructies voor gebruik UVC drukfilterset S Bruksanvisning UVC tryckfilterset I Istruzioni per l uso Set filtro a pressione UVC E Manual de instrucciones Juego de filtros a pres...

Страница 2: ...Range of Uses forYour GARDENA UVC Pressure Filter Set The UVC Pressure Filter Set is intended for private use in domestic gardens and allotments and should only be used out of doors for cleaning gard...

Страница 3: ...t When newly installed the UVC Pressure Filter Set only reaches its full biological cleaning effect after a few weeks Extensive bacteria activity only takes place from a temperature of 10 C or above H...

Страница 4: ...ansformer v Please contact your electrician For Switzerland In Switzerland mobile appliances which are used outdoors must be connected via a residual current device Note Operation of the pressure filt...

Страница 5: ...s This promotes the growth of micro organisms which guarantee the conversion of ammonia into nitrate via nitrite nitrification Lava stone This supports the growth of anaerobic micro organisms which pr...

Страница 6: ...the surface of the pond When using a stream the maximum height must not be exceeded 1 Bury or position the pressure filter D securely at least 2 m away next to the garden pond and above the surface of...

Страница 7: ...nce DANGER Electric shock A v v Before undertaking maintenance unplug the UVC unit and the pump from the mains WARNING Danger of the container bursting A v v Do not connect the pressure filter to the...

Страница 8: ...ing water 7 Assemble the pressure filter again in reverse order Ensure that the O Ring O is sitting correctly 8 Start operation of the pressure filter again see 5 Initial Operation Operating the UVC P...

Страница 9: ...he UVC unit in reverse order DANGER Short circuit A v v The ring U must be screwed on firmly again to guarantee that the glass tube T is sealed During assembly ensure that the O Ring X on the glass tu...

Страница 10: ...res or an authorised repairer If any other faults arise please contact GARDENA Service 9 Accessories GARDENA 1 Hose for use as inflow Art 7831 Ribbed pond hoses or outflow hose 10 Technical Data PF 10...

Страница 11: ...d in keeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The wearing parts UVC bulb filter materials and...

Страница 12: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Страница 13: ...urit et autres r gles qui lui sont applicables dans le cadre de l Union europ enne Toute modification port e sur ce produit sans l accord express de GARDENA supprime la validit de ce certificat N EU o...

Страница 14: ...di rendimento Curva caracter stica de la bomba Caracter sticas de performance Ydelses karakteristika PF 10000 S Art 7872 Pumpen Kennlinie Performance characteristics Courbes de performance Prestatieg...

Страница 15: ...k ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Phone 39 02 93 94 79 1 info gardenaitalia it Japan K...

Отзывы: