Cleaning the UVC unit :
Cleaning the pump :
C
P
Q
1. Unplug the mains plug of the UVC
unit and pump.
2. Turn the cap
J
of the UVC unit
1
and remove carefully
2
(bayonet
fitting).
3. Clean the glass tube
L
(using liquid
glass cleaner, for example).
4. Fit the UVC unit again in reverse
order.
When assembling, ensure that the
O-ring
N
is inserted correctly in
the cover
J
and that the arrow
markings
O
are aligned opposite
one another.
Cleaning the pump filter housing :
The water intake slots on the water feature pump must be free
from dirt.
1. Unplug the pump and the UVC unit from the mains.
2. Remove the pump from the pond.
3. Unscrew threaded sleeve
P
and connection piece
C
.
4. Open up the pump filter housing
Q
and spray clean with
a jet of water.
5. Clean the water intake slots of the filter housing
Q
with
a brush.
Note :
Do not use any hard objects or powerful detergents for
cleaning the set !
Remove dirt deposits in the pump :
1. Unplug the pump and the UVC unit from the mains.
2. Remove the pump from the pond.
3. Unscrew threaded sleeve
P
.
4. Open up pump filter housing
Q
and remove the pump.
5. Open the snap hook
R
and take the pump cover
S
off the motor housing
T
.
6. Draw the impeller unit
U
out of the motor housing
T
.
7. Remove any dirt deposits from pump components.
8. Replace the impeller unit
U
in the motor housing
T
.
9. Press the pump cover
S
into the motor housing
T
until
the connection is heard to snap into place.
7. Trouble-Shooting
The UVC bulb should be replaced after approximately 8,000 oper-
ating hours since the UVC performance decreases dramatically
after this time.
Only bulbs of type 9 W TC-S (UV-C) should be used
(e. g. Radium: Puritec NSE 9-270, Philips: TUV PL-S 9 W or
Sylvania: G 9 LYNX-S GERMICIDAL). The UVC lamp can be
ordered as a replacement part from GARDENA Service.
Changing the bulb :
1. Unplug the mains plug of the UVC unit and pump.
2. Turn the cap
J
of the UVC unit
1
and
remove carefully
2
(bayonet fitting).
3. Carefully unscrew the ring
K
.
4. Pull off the glass tube
L
.
(It may be relatively difficult to re-
move the glass tube due to mineral
deposits.)
5. Take out the bulb
V
and replace it
with a new one.
6. Reassemble the UVC unit in reverse
order.
When assembling, ensure that
the O-ring
N
fits properly on the
glass tube
L
, that the O-ring
N
is inserted correctly in the cover
J
and that the arrow markings
O
are aligned opposite one another.
Due to the integrated safety switch the lamp only comes on
when the UVC unit is properly installed.
Fault Possible
Cause
Remedy
The water is not clear.
The pond is extremely dirty
1. Check nitrate concentration
and rich in nutrients.
(e. g. with the GARDENA
Pond Test Set, Art. No.
7920).
2. If necessary, change the
water and clean the pond.
Filter pellets dirty.
v
Clean filter pellets
(see
6. Maintenance
„Cleaning the filter“
).
Too many fish and creatures
v
Add up the estimated length
in the pond.
of the fish.
There should only be “80 cm
fish” per m
3
water in the pond.
The glass tube of the UVC unit
v
Clean UVC unit
is dirty.
(see
6. Maintenance
).
Pump does not work.
Electrical connections defective.
v
Check electrical connections.
Impeller unit blocked.
v
Remove dirt deposits in
the pump (see
6. Main-
tenance
).
The UVC pilot light is not on.
Bulb defective.
v
Change bulb.
Electrical connections defective.
v
Check electrical connections.
The cap
J
has not snapped
v
The cap is fitted correctly
properly into place.
when the two arrow mark-
ings
O
are in alignment
with one another.
If any other faults arise, please contact GARDENA Service.