Problem Probable
cause
Remedy
Pump runs, but the suction
Air cannot escape, since
v
Open all possible shut-off
action doesn’t take place
delivery side is closed
devices (e.g. spray nozzle)
or remaining water is in the
in the pressure line, or drain
pressure hose.
the pressure hose or dis-
connect it during the suction
action.
The waiting time wasn’t
v
Switch on the pump and
observed.
wait max. 7 min.
Suction filter or backflow preventer
v
Clean the filter or the back-
in the suction hose clogged.
flow preventer.
Too high suction height.
v
Reduce suction height.
In case of any other difficulties concerning the suction action,
use GARDENA Suction Hoses with Backflow Preventer (see
point 8. Accessories) and fill in the liquid to be pumped over the
filler cap
2
before operation.
Pump motor runs, but
Suction filter at the suction
v
Reduce flow rate on the
delivery capacity or pressure
hose is sucked free.
delivery side with a control
suddenly decreases
valve, e.g. GARDENA
art. no. (2)977.
Suction filter or backflow
v
Clean filter or back-flow
preventer clogged.
preventer.
Leaks at suction side.
v
Eliminate leak.
Turbine clogged.
v
Loosen the turbine.
Pump motor doesn’t start
No power.
v
Check fuses and electric
or suddenly stops
connections.
Thermal overload switch
v
Take care of cooling /
has cut out the pump due
ventilation.
to overheating / overloading.
Electric failure.
v
Send the pump to one of our
GARDENA Service Centres.
A
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
authorised by GARDENA.
7. After Operation
You should empty your Garden Pump
before the first frost sets in.
1. Open the water drain screw
B
.
The Garden Pump drains.
2. Store your Garden Pump so that
it is protected from frost.
The product must not be added to normal household waste. It
must be disposed of in line with local environmental regulations.
v
Important : Make sure that the unit is disposed of via your
municipal recycling collection centre.
Wintering / Storage :
B
Disposal :
(in accordance with
RL 2002 / 96 / EC)
GB
15