Setting up your 
Garden Pump :

Filling the pump : 

WARNING ! 
Electric shock ! 

Connecting hose 
to suction side : 

Connection hose 
to delivery side : 

1

2

4

3

z

3a

3. Initial Operation 

The site must be firm and solid in order to ensure safe and sturdy
operating conditions for the pump. 

v

Position the pump at a safe distance from the liquid to be 
pumped. 

The pump must be installed in a location with low air humidity
and sufficient ventilation in the area of the ventilation slots. It 
must be at a distance of at least 5 cm from the walls. No dirt 
contamination (e.g. sand or earth) may be sucked in through 
the ventilation slots. 

Dry-Running 

A

Before each operation, fill the pump to overflowing 
with approx. 2 to 3 l of the liquid to be pumped ! 

Risk of injury due to electric shock.

V

Disconnect from the mains before filling the Pump. 

1. Unscrew the screw fitting 

1

of the filler cap 

2

by hand. 

2. Fill the pump via the filler cap 

2

to overflowing with approx. 

2 to 3 l of the liquid to be pumped. 

3. Tighten the screw fitting 

1

of the filler cap 

2

by hand (do not

use pliers). 

The fittings on the input and output side may only be tightened 
by hand. Don’t use any hose connection system fittings on the
suction side ! A vacuum-resistant suction hose must be used 

e.g. GARDENA Suction Unit, 

art. no. 1411

In order to reduce the suction time, it is advisable to use a suction
hose with backflow preventer avoiding automatic draining of the
suction hose when the pump is stopped. 

1. Screw a vacuum-resistant suction hose airtight onto the 

connector 

3

on the suction side of the pump 

4

2. For suction heights exceeding 4 m also secure the suction 

hose (e.g. by fastening it to a wooden post). 
This relieves the pump of the weight of the suction hose. 

Both pump connectors

z

3a

a are equipped with a 33.3 mm (G 1)

thread to which 13 mm (

¹⁄₂

" ), 19 mm (

³⁄₄

" ) and 16 mm (

⁵⁄₈

" ) hoses

can be connected by using GARDENA hose connection system 
fittings. The back pump connector is closed with an end cap.
Unscrew the end cap for connecting two hoses. 
For vertical connection (e.g. Electronic Manometric Switch, 
Art. No. 1739) an additional end cap is necessary. 
It can be obtained free of charge from your GARDENA Service
Centre. 

GB

12

Содержание 4000/4 Inox Multi 3

Страница 1: ...uik Beregeningspomp S Bruksanvisning Bevattningspump DK Brugsanvisning Trykpumpe I Istruzioni per l uso Pompa da giardino E Manual de instrucciones Bomba para jard n P Instru es de utiliza o Bomba de...

Страница 2: ...g 14 7 After Operation 15 8 Accessories 16 9 Technical Data 16 10 Service Warranty 17 1 Where to Use Your GARDENA Garden Pump GARDENA Garden Pumps have been designed for private use around house and g...

Страница 3: ...t be connected via a residual current device Environment v Protect the pump from rain Don t use the pump in wet or moist area Visual check v Before operating the pump first make a visual cheek if ther...

Страница 4: ...Tighten the screw fitting 1 of the filler cap 2 by hand do not use pliers The fittings on the input and output side may only be tightened by hand Don t use any hose connection system fittings on the s...

Страница 5: ...per missible internal pressure of 6 bar on the delivery side must not be exceeded The to be increased delivery pressure and the pump pressure sum up Example pressure at the water tap 1 5 bar max pres...

Страница 6: ...8 using a screwdriver Thereby the clogged turbine is loosened Problem Probable cause Remedy Pump runs but the suction You didn t fill the pump with v Fill in liquid see point action doesn t take plac...

Страница 7: ...denly decreases valve e g GARDENA art no 2 977 Suction filter or backflow v Clean filter or back flow preventer clogged preventer Leaks at suction side v Eliminate leak Turbine clogged v Loosen the tu...

Страница 8: ...operating pressure With dry running safety GARDENA Prevents the pump from dama Art no 1741 Dry Running Safety ges in case of missing liquid GARDENA For vacuum resistant connection Art no 1729 Bore Hol...

Страница 9: ...eping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The turbine is a wearing part and is not covered by th...

Страница 10: ...gegevens in de grafiek zijn gemeten bij een aanzuig hoogte van 0 5 m en bij gebruik van een 25 mm 1 aanzuig slang V rdena ovan r utm tta p en sugh jd av 0 5 m med 25 mm 1 sugslang Tekniske data for de...

Страница 11: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Страница 12: ...igheid S EU Tillverkarintyg Undertecknad firma GARDENA Manufacturing GmbH Hans Lorenser Str 40 D 89079 Ulm intygar h rmed att nedan n mnda produkter verensst mmer med EU s direktiv EU s s kerhetsstand...

Страница 13: ...bH Hans Lorenser Stra e 40 D 89079 Ulm vakuuttaa ett allamainitut laitteet t ytt v t tehtaaltamme l h tiess n yhdenmukaistettujen EY direktiivien EY turvallisuusstandardien ja tuotekohtaisten standard...

Страница 14: ...Phone 36 80 20 40 33 gardena gardena hu Iceland Johnson Kaaber Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p...

Отзывы: