Gardena 4000/4 Inox Multi 3 Скачать руководство пользователя страница 5

WARNING ! 
Electric shock ! 

Pumping liquid : 

7

6

Best results regarding the delivery capacity of the pump are
achieved when connecting 19 mm (

³⁄₄

" ) hoses in conjunction 

with e.g. 

GARDENA Pump Connection Set, 

art. no. 1752

, or when 

using 25 mm (1

" ) hoses with fittings available from your 

sanitary dealer.  

v

Connect the pressure hose to the connector

z

3a

on the delivery

side 

5

When connecting simultaneously more than 2 hoses / accessories
we recommend application of the 

GARDENA 2- or 4-way distributor, 

art. no. 1210 / 1194

, which 

can be screwed directly on to the pump connection

z

3a

4. Operation 

The indicated self-priming suction height (see point 9. Technical
Data) can be achieved only if the pump has been filled over the
filler cap to overflowing and if during the filling as well as during
the self-suction the suction hose is held upwards so that no liquid
can be get off the pump through the suction hose. 

When using the pump for pressure intensification, the max. per-
missible internal pressure of 6 bar (on the delivery side) must
not be exceeded. The to be increased delivery pressure and the
pump pressure sum up. 

Example: pressure at the water tap 1.5 bar, max. pressure of
the GARDENA Garden Pump 4000 /4 Inox Multi 3 3,6 bar, 
total pressure 5,1 bar. 

Risk of injury due to electric shock.

V

Disconnect from the mains before filling the 
Garden Pump. 

1. Fill the pump to overflowing with approx. 2 to 3 l of the liquid 

to be pumped (see 3. Initial Operation, 

“Filling the Pump” ).

2. Open all possible shut-off devices in the pressure line 

(watering accessories, Water Stop, etc.).

3. Drain remaining water in pressure hose so that air can escape

during the suction process.

4. Set On / Off switch 

6

to position 

“0”

position.

5. Plug the pump into a 230 V / 50 Hz alternating current socket.

6. Set On / Off switch 

6

to position 

“I”

position.

7. Hold the hose 

7

at the delivery side approx. 1 m vertically

above the pump until the pump begins to pump. 

The pump should begin to deliver liquid after 7 minutes at the
latest.

v

If the pump does not deliver liquid after 7 minutes, set the
On / Off switch

6

to position 

“0”

(see 6. Trouble-Shooting).

5

z

3a

GB

13

Содержание 4000/4 Inox Multi 3

Страница 1: ...uik Beregeningspomp S Bruksanvisning Bevattningspump DK Brugsanvisning Trykpumpe I Istruzioni per l uso Pompa da giardino E Manual de instrucciones Bomba para jard n P Instru es de utiliza o Bomba de...

Страница 2: ...g 14 7 After Operation 15 8 Accessories 16 9 Technical Data 16 10 Service Warranty 17 1 Where to Use Your GARDENA Garden Pump GARDENA Garden Pumps have been designed for private use around house and g...

Страница 3: ...t be connected via a residual current device Environment v Protect the pump from rain Don t use the pump in wet or moist area Visual check v Before operating the pump first make a visual cheek if ther...

Страница 4: ...Tighten the screw fitting 1 of the filler cap 2 by hand do not use pliers The fittings on the input and output side may only be tightened by hand Don t use any hose connection system fittings on the s...

Страница 5: ...per missible internal pressure of 6 bar on the delivery side must not be exceeded The to be increased delivery pressure and the pump pressure sum up Example pressure at the water tap 1 5 bar max pres...

Страница 6: ...8 using a screwdriver Thereby the clogged turbine is loosened Problem Probable cause Remedy Pump runs but the suction You didn t fill the pump with v Fill in liquid see point action doesn t take plac...

Страница 7: ...denly decreases valve e g GARDENA art no 2 977 Suction filter or backflow v Clean filter or back flow preventer clogged preventer Leaks at suction side v Eliminate leak Turbine clogged v Loosen the tu...

Страница 8: ...operating pressure With dry running safety GARDENA Prevents the pump from dama Art no 1741 Dry Running Safety ges in case of missing liquid GARDENA For vacuum resistant connection Art no 1729 Bore Hol...

Страница 9: ...eping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The turbine is a wearing part and is not covered by th...

Страница 10: ...gegevens in de grafiek zijn gemeten bij een aanzuig hoogte van 0 5 m en bij gebruik van een 25 mm 1 aanzuig slang V rdena ovan r utm tta p en sugh jd av 0 5 m med 25 mm 1 sugslang Tekniske data for de...

Страница 11: ...n om skadan beror p att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra n Original GARDENA reservdelar har anv nts Samma sak g ller f r kompletteringsdelar och tillbeh r...

Страница 12: ...igheid S EU Tillverkarintyg Undertecknad firma GARDENA Manufacturing GmbH Hans Lorenser Str 40 D 89079 Ulm intygar h rmed att nedan n mnda produkter verensst mmer med EU s direktiv EU s s kerhetsstand...

Страница 13: ...bH Hans Lorenser Stra e 40 D 89079 Ulm vakuuttaa ett allamainitut laitteet t ytt v t tehtaaltamme l h tiess n yhdenmukaistettujen EY direktiivien EY turvallisuusstandardien ja tuotekohtaisten standard...

Страница 14: ...Phone 36 80 20 40 33 gardena gardena hu Iceland Johnson Kaaber Tunguhalsi 1 110 Reykjavik ooj ojk is Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p...

Отзывы: