OPERATING INSTRUCTIONS
Lighting Instructions
Lighting Instructions
1. Ensure the LP-gas cylinder valve and the item's
control knob are in the "OFF" position. If not, turn off and
wait 5 minutes for any gas to clear.
2. Turn the LP-gas cylinder valve "ON" and push the
item's control knob in and rotate it to "PUSH." Then,
push the item's igniter button and control knob until
the burner lights. Note: If the burner fails to remain
lit or is extinguished, repeat step 2 after waiting the
necessary 5 minutes when completing the shutoff
process.
3. Once the burner has lit, continue to hold the control
knob in for 30 seconds, then release.
4. Turn the control knob from "LOW" to "HIGH" until
the desired heat setting is reached.
5. Visually check the burner flame against the
illustrations below:
1) Flame should be blue with slight yellow tips.
2) You should see a smaller flame in LOW position
than seen on HIGH. Perform flame check prior
to each use. If only low flame is seen, refer to
“Burner flame is low” in the
“TROUBLESHOOTING” on page 16.
1
For complete shutdown:
1. Turn the item's control knob to "PUSH", then push and turn to "OFF" for a complete shutoff.
2. Turn the LP-gas cylinder valve to the "OFF" position, then remove the tank, if desired.
Checking for Leaks
a. Make leak solution by mixing 1 part liquid dish soap and 3 parts water.
b. Spoon or brush several drops (or use squirt bottle) of the solution onto the gas hose/regulator and
regulator/cylinder and hose connections.
c. Turn on gas cylinder valve. Inspect the connections and look for bubbles.
1. If no bubbles appear, the connection is safe.
2. If bubbles appear, there is leakage. Loosen and re-tighten this connection. If it still leaks, please call
customer service.
Note:
Whenever gas connections are loosened, removed or re-assembled, you must perform a complete
leak test.