RC1xx LED Lighting Controllers - User Manual
—
27
—
Follow the keystrokes below to enter numerical data into the RC1xx using
the scheme shown.
E-2
is displayed. Press the
SEL
button.
Use the
and
buttons to select the
required value in steps of 10ms. Press the
SEL
button.
Use the
and
buttons to scroll to
E-3
to enter time values from 1ms to 999ms.
Press the
SEL
button.
Use the
and
buttons to select the
required value in steps of 1ms. Press the
SEL
button.
Use the
and
buttons to scroll to
E-4
to enter time values from 0.1ms to
99.9ms. Press the
SEL
button.
Use the
and
buttons to select the
required value in steps of 0.1ms. Press the
SEL
button.
10.2.7 Setting the internal trigger timer
You can set an internal trigger timer when the RC1xx is in pulse mode.
When set, the RC1xx triggers with the same delay and pulse width already
set up as described in Section 10.2.5, “Setting up pulsed operation”.
External triggering remains enabled.
Ensure the RC1xx is set to pulsed operation. To set the period of the
internal trigger timer, press and hold
SEL
for 1 second, and follow the
keystrokes below:
CH1
is displayed. Press the
SEL
button.
Use the
and
buttons to scroll to
FrE
and press the
SEL
button.
OFF
is displayed. Use the
and
buttons to scroll to
ON
to set up the
internal trigger. Press the
SEL
button.
Set up the internal trigger timer as
described in Section 10.2.6 “Setting time
periods”. Press the
SEL
button.