CL190/CL191 Lens Controller - User Manual
10.3
Error codes
Error
number
Reason
Err 1
A parameter value is invalid.
Err 2
Command not recognised.
Err 3
A numeric value is in the wrong format.
Err 4
Wrong number of parameters.
Err 5
This is a warning, not an error. One of the parameters is
out of range and the value of that parameter has been
adjusted.
Err 8, 12
EEPROM corrupt. The configuration has been cleared.
Err 9, 20
Settings could not be saved to EEPROM.
Err 27
Serial number cannot be read from EEPROM.
Err 192
Unable to read EEPROM in lens.
Err 193, 194,
195
Lens EEPROM format is wrong.
Err 196
Current required for the optical power by the lens is
more than the lens is rated for or more than the con-
troller can supply.
Err 197
Lens temperature is outside its operating range.
—