CL190/CL191 Lens Controller - User Manual
Where:
m
= 0 to trigger on a positive-going source
m
= 4 to trigger on a negative-going source
Save the settings to memory
AW
This command saves the settings to non-volatile memory. If you
power cycle the CL190 before sending the
AW
command, all
changes are lost and the unit returns to the values set before the last
AW
command.
Clear configuration
CL
This command clears the configuration and lighting ratings, and
turns the output off. The results of any
RS
,
RU
,
RA
,
RE
, and
AW
commands are cleared.
This command shows the configuration of the CL190. Type in:
ST
A typical reply to this command might be:
CH1,MD0,AF 3.95, IF 0.00,
IP1,FL0,Mn0.0,Mx0.
Where :
CH
Channel number; this is always
1.
MD
Mode: 0 = continuous, 1 = switched, 2 = analog.
AF
Active optical power in the range of the connected
lens.
IF
Idle optical power in the range of the connected lens.
IP
Always returns IP1
RT
Retrigger delay.
IP
Always returns IP1.
FL
Flags set using the
RE1
command.
Mn
In Analog mode, the voltage corresponding to
minimum focus.
Mx
In Analog mode, the voltage corresponding to
maximum focus.
—
20
—
Содержание CL190
Страница 1: ...CL190 CL191 Lens Controller Issue 002 User manual www gardasoft com...
Страница 4: ...CL190 CL191 Lens Controller User Manual 4...
Страница 16: ...CL190 CL191 Lens Controller User Manual 16...
Страница 35: ...CL190 CL191 Lens Controller User Manual This page is left blank for your notes 35...