CL190/CL191 Lens Controller - User Manual
Set lens with no EEPROM
The CL190 will work with Optotune™ lenses having no internal
EEPROM. This command allows the user to set the optical power
and current rating for the lens.
RM1,n,x,i,a
Where:
n
-
minimum optical power
x
-
maximum optical power
i
-
current for minimum optical power
a
-
current for maximum optical power.
And:
RM1
Require lens EEPROM (default).
When using a lens with no EEPROM, there are various features
which are not available, such as temperature compensation.
When the command has been used to set a lens with no EEPROM,
the TR-CL180 will ignore the lens’s EEPROM and will continue to
ignore it until the
RM1
command has been sent.
Caution:
Using the wrong parameters can damage the lens. Only
use this command with parameters supplied by Gardasoft or
Optotune.
Read the current optical power of the lens
RL"CH1_LNOUT"
Read the minimum optical power for the lens
RL"CH1_LNMIN"
Read the maximum optical power for the lens
RL"CH1_LNMAX"
Read the lens serial number
RL"CH1_LNSER"
Read the lens temperature
RL"CH1_LNTMP"
Read the analog input voltage
RL"CH1_MADV"
—