www.garantia.eu
13 / 32
Rohrlänge inkl. Muffe:
3700 Liter = 138 cm
4500 Liter = 157 cm
6500 Liter = 195 cm
9000 Liter Set = 157 cm
(alle Maße +/- 3% Toleranz)
beruhigter Zulauftopf
SUPRA-Filter intern
Schraube
5.
Installation and assembly
5.1 SUPRA
®
-Filter internal / Columbus underground tank
The SUPRA
®
-Filter Internal is prepared as shown
in the adjacent depiction. The filter housing is
connected via the on site installed canalisation
pipe to the stabilising inlet well (included in the
Filter package SUPRA). The couplings should be
secured with commercial self tapping screws.
Following this a 250 mm long inlet pipe and an
overflow siphon are pushed in to the Columbus
underground tank until the end stop position as
shown in the adjacent depiction.
Now the prepared SUPRA®-Filter internal is
installed in the tank, the elbow of the overflow from
the filter is also connected now to the siphon. The
inlet pipe is so to position that it is flush with the
filter inlet and then finally fixed in place with the
quick assembly collar.
Under no circumstance may a mesh barrier to
prevent small animals entering the tube be
installed as this will eventually lead to a blockage
from debris in the pipe.
Pipe length with bush:
3700 L = 1380 mm
4500 L = 1570 mm
6500 L = 1950 mm
9000 L Set = 1570 mm
*(all dime/- 3% Tolerance)
settled inlet basked
Screw
SUPRA-Filter internal
Overflow-
siphon DN 100
Inflow DN 100
L: 250 mm
SUPRA-Filter internal
Quick assembly
sleeve
settled inlet basked
Overflow-siphon DN 100