8-14. CONNECT TO POWER
To reduce the risk of electric shock, your opener is provided with an
insulated power cord with a 3-prong grounding plug. The cord must be
connected to a standard grounding outlet. If there is no outlet available at
the location, you must have a qualified electrician install an approved
grounded outlet in this area.
Grounded Outlet
Power Cord
Fig. 28
Wires: (remaining 6”)
Ground (Green)
Hot (Black)
Neutral (White)
Strain relief
Fig. 29
Nylon cable tie
Fig. 29A
• Plug the operator into a properly grounded outlet (see Fig.28).
• An indicator lights (LED’s #4 and #8) on the operator control panel will
turn on showing that the power is “On” and the opener is ready to set
the adjustments.
• DO NOT operate or run the opener at this time.
PERMANENT WIRING CONNECTION:
(If required by your local electrical code)
If local codes require your operator to be connected via permanent wiring
instead of a cord and plug, your operator must be converted, (see Fig. 29).
Contact a qualified electrician to run the necessary wiring to your
operator and to perform the electrical connections.
• Remove operator housing by removing the four screws, two screws
located at the front by the control panel area, and two screws located on
the back of the unit, then pulling the housing away from the chassis.
• Cut the power cord close to strain relief cover, so that after cut, there is
at least 6” of wiring remaining. Remove approx. 1 ½” of black insulation
left on the cable to expose the three conductor leads (white-neutral,
black-hot, and green-ground).
• Remove screw and unsnap the power cord strain relief cover by
disengaging the tabs, and remove this part (save for reattachment later).
• Remove the cut power cord and discard. Replace the strain relief cover
by snapping tabs back into place.
• Using a hammer and screwdriver or punch, knock out conduit hole, and
bring in the permanent wiring and conduit.
• Secure conduit to chassis (method varies depending on type of conduit used).
• Attach the incoming power leads (hot, neutral, and ground) to the
remaining internal wires using suitable wire nuts (not provided). Tight
wire leads together with a nylon cable tie to avoid the leads from coming
in contact with the relay circuit board, (see Fig. 35A).
• Reinstall operator housing and secure housing with screws. Make sure
that when reinstalling operator housing, no wires will be pinched between
the housing and the chassis.
• Complete the remaining installation.
• Turn on power at breaker.
Warning
To prevent electrocution, disconnect the operator from
power and turn off power at circuit breaker for the
circuit you will be using to connect to the opener.
Warning
To prevent electrocution or fire, installation and wiring
must be done in accordance with local electrical and
building codes. DO NOT use an extension cord. DO NOT
use a 3 to 2 plug adapter. DO NOT modify or cut off the
grounding pin on the plug.